STACKED AND POLE-MOUNTED DEPLOYMENTS OF THE TOWER SYSTEM
Procedures
Installing Sub Pole Cup on CSUB610
In order to deploy an LCC44 unit in a sub/satellite configuration atop
a SUB310 or CSUB610 subwoofer unit, the subwoofer must first be
equipped with a Sub Pole Cup.
Figure 26. Removing CSUB610
cover plate.
•
Using a 4 mm hex wrench, remove the four screws retaining
the pole cup cover on the upper side of the CSUB610 cabinet,
and remove the cover plate.
Figure 27. Inserting the Sub Pole Cup into
CSUB610.
•
Insert the Sub Pole Cup flange into the recess in the cabinet
and seat it firmly.
•
Re-insert the screws that retained the plate into the four
countersunk holes in the Sub Pole Cup, and thread them into
the inserts below the cup.
Figure 28. Fixing the Sub Pole Cup to CSUB610
•
Again, using the 4 mm hex wrench, tighten the four screws
firmly.
Installing Outriggers on the CSUB610
Installing the subwoofer outriggers improves the stability of the CSUB610
or SUB310 when deployed vertically on the floor. The outriggers are
recommended in any application in which the subs are deployed in
public areas where people could bump into them or lean on them.
These are also REQUIRED in any application in which other loudspeaker
enclosures are coupled to the subwoofer in an upright position. The
CSUB610 unit can be deployed with LCC44, LCC84 or combinations of
these in either a parallel or perpendicular configuration. Each of these
configurations requires that the outriggers be installed in the appropriate
configuration.
WARNING
TIPPING HAZARD
Speaker enclosures stacked atop one another, even
when properly coupled, represent a tipping hazard.
TO
REDUCE
THE
RISK
OF
INJURY
OR
DAMAGE THAT COULD RESULT FROM POSSIBLE
TOPPLING OF LOUDSPEAKER ENCLOSURES,
THE INSTALLATION OF THE SUBWOOFER
OUTRIGGERS ON THE SUB310 AND CSUB610
IS REQUIRED WHENEVER ONE OR MORE
LOUDSPEAKER ENCLOSURES IS MOUNTED
ATOP ONE OF THESE UNITS, EITHER IN A
STACKED CONFIGURATION USING THE TOWER
RIGGING SYSTEM OR IN A SUB/SATELLITE
CONFIGURATION USING A SPEAKER POLE.
Installing Outriggers for parallel (cardioid) deployment of
CSUB610 with LCC44/84
If the application requires the use of the cardioid functionality of
CSUB610 on axis with the LCC84 or LCC44 unit(s), the Outriggers must
be installed on the subwoofer in the parallel configuration, with the two
50°-angled outriggers extending forward to provide extended stability
at the front of the cabinet, while the two 90° outriggers are installed at
the rear. Naturally, this configuration can be used with omnidirectional
presets on the subwoofer, as well, but only when the LCC44 or LCC84
units are coupled parallel to the CSUB610, with all the forward grilles
facing the same direction.