background image

 

4.  Set up Instructions

 

 

                                                                                                                                       

4.1 Special note on responsibility for watertight integrity   

 

Each housing is individually inspected and hydrostatically tested in the factory. The design of the main piston 

O-ring seal is among the most reliable in the industry and the watertight integrity is excellent. This special 

O-ring design provides a perfect seal even if there is any movement between the body and lid due to change 

of ambient pressure. However please note that responsibility for ensuring the integrity of the watertight seal 

lies entirely with the user. 10BAR accepts no liability for damage to, or loss of any equipment used with, or 

placed inside the housing. Users are highly recommended to carry out in-water test of the housings without 

installing of the camera for their first dive, after change of new ports or alternation of any new configuration. 

The test can be carried out by lowering the housing with ballast to the working depth or dive down to the safe 

diving range.

 

 

 

 

The O-ring seal is the main barrier between the water outside and the air space within the camera. 

It is an effective barrier only if the seal is properly maintained. The O-ring seal should be inspected 

before every dive. The following information is provided for your guidance in using and 

maintaining the O-ring seal.   

     

 

4.2 Maintaining the O-ring Seal 

 

If the main body to lid O-rings are not installed, install the 

O-rings before diving. Their care and maintenance are 

critical to the watertight integrity of the housing. If the 

O-rings are contaminated, or not already installed; inspect, 

grease and install the O-rings according to the following 

guidelines.

   

 

 

 

 
 

 

4.3 Inspection, cleaning and re-instillation of the O-rings   

 

Tools   

 

A soft cotton bud or sponge applicator, make sure these are free of all chemicals or contamination such 

as loose fibers, and the tube of silicone grease supplied with the housing. Note other types of silicone 

grease specifically for use with underwater camera equipment can usually also be used. It is advised to 

carry out the following procedure on a firm clean level surface, (e.g. at a table), to prevent skidding 

especially when diving from a boat.   

Summary of Contents for G11

Page 1: ...rchangeable ports for conversion lens The acrylic back cover allows taking pictures and checking on the camera much easier For closure the double o rings and key hole lock design provide ease of use and added security Now you can use small cameras with the feel and function of professional housings 2 Specifications Test Pressure Housings individually tested to 10 Bar 90 m 300 ft Recommended workin...

Page 2: ... and extension adaptor optional Housing for 580EXII Flash optional 3 Function Controls 3 1 Buttons Parts 1 EXPOSURE COMPENSATION DIAL 2 BULKHEAD 3 MODE DIAL 4 ISO SPEED DIAL 5 ZOOM 6 SHUTTER 7 POWER ON OFF 8 SHORTCUT PRINT SHARE 9 PLAYBACK 10 AE LOCK FE LOCK MICROPHONE BUTTON METERING LIGHT JUMP BUTTON AF FRAME SELECTOR SINGLE IMAGE ERASE BUTTON 11 FUNCTION SET 12 4 WAY BUTTON 13 CONTROL DIAL 14 D...

Page 3: ... press down to activate the function 9 PLAYBACK press to activate 10 AE LOCK FE LOCK MICROPHONE BUTTON METERING LIGHT JUMP BUTTON AF FRAME SELECTOR SINGLE IMAGE ERASE BUTTON rotate until the white dot is over the required button and press to activate 11 FUNCTION SET rotate until the white dot align and press 12 4 Way BUTTON rotate until the white dot align and press when not in use rotate the whit...

Page 4: ...g range The O ring seal is the main barrier between the water outside and the air space within the camera It is an effective barrier only if the seal is properly maintained The O ring seal should be inspected before every dive The following information is provided for your guidance in using and maintaining the O ring seal 4 2 Maintaining the O ring Seal If the main body to lid O rings are not inst...

Page 5: ...enance only if necessary Procedure How to open the housing Place the lid on a firm non slip level surface The O ring can be extracted using an O ring extractor tool make sure the tool as no sharp edges Alternatively use the flats of the thumbs to gently stretch the O ring on two faces thus making a small loop protruding a few mm The loop can then be grasped between finger and thumb to pull the O r...

Page 6: ... round the O ring Replace the O ring into the groove run a finger round the O ring to make sure it is snugly seated in the groove 4 4 Key hole lock Select the key hole lock easy for using and security Pull out the key from the lock hole on both sides and screwed tight the key to balance with automatic release Pull out the lid by holding on the grip near the lock ...

Page 7: ... into the body along the guide rail Make sure the camera body reach the limit and test the function of the on of button on the body of the housing Slide the hot shoe plug into the hot shoe Note If you find that the buttons do not align properly with the controls please check again the camera is properly seated to the limit of the guide rail Slide the camera into the body along the rubber packing M...

Page 8: ...e mode Connect the strobe sync cord to housing s bulkhead sync port On the side of the housing port notice a simple alignment indicator dot The sync cord contains a small channel groove between two of the female pins of the cord You must insert the cord into the port so the groove is aligned with the indicator of the housing This assures proper alignment Hold firmly in place while fastening lockin...

Page 9: ...standing strength stiffness hardness and toughness While Acrylic for its crystal clear transparency and high gloss surface Both of them have good resistance to weathering although long term exposure to sunlight should be avoided Normal operating temperature range is 3 C to 36 C Storage temperature 10 C to 50 C It is good practice to rinse off your housing with fresh water after every dive Avoid to...

Page 10: ...used inside or used together with the housing In the event of the housing flooding within the period of warranty 10BAR will repair or replace the housing Please note that disassembly of the housing will invalidate warranty Please fill in the information below and return a copy to 10Bar Underwater Housing at the address below to validate the warranty Copy to be retained by user Housing Type Date of...