background image

2

  |  Eleven Hundred Energy Corporation

Turn-on/Wake-up from Hibernation 

Hibernation: 

The SBP-1100e will automatically enter a hibernation state after 30 minutes of non-use (and provided 

that no live charging power source is connected). This is done to conserve the stored energy which powers the unit, and 

thereby extend the energy-retention shelf-life of the unit.  

Press RESET to wake up: 

To turn on or wake up the unit, press firmly with a fingertip on the small silver dot labeled 

‘RESET’, and release. The RESET dot is located just to the left of the SCROLL button on the LCD control panel on the top 

face (hinged lid) of the SBP-1100e. Within 3 seconds, the SBP-1100e will wake up and begin to initialize, flashing mes-

sages on the LCD screen.

If needed, connect power to wake up:

 An SBP-1100e unit which holds a 50% charge when entering hibernation, and 

which has remained in hibernation for a few weeks or less, should be able to be awakened by pressing the RESET dot. 

Should the unit become completely exhausted while in hibernation, pressing the RESET dot will not awaken the unit. 

In that case, connect a charging power source, such as the SBP AC Power Adapter, item no. SBP-AC-ADAPTER-24VDC-

130W, to the INPUT receptacle on the left side of the SBP-1100e. Be sure the AC Adapter is plugged into a live AC out-

let, and that the adapter power switch is on. Within 3 seconds, the unit should wake up and begin to initialize, flashing 

messages on the LCD screen. If not, contact 1100 Energy for assistance.

Press SELECT to view product ID:

 the initialization process takes, one minute until the LCD display goes blank, except 

for a row of grey raster rectangles which may appear dimly on the LCD screen.
After the display goes blank, wait one more minute (or less) for initialization to complete, then press the SELECT button 

to see the product identification and software version. The software version should match the software version listed on 

the cover of this User Manual. 

Press SCROLL to view mode and charge state: 

Press the SCROLL button to view the state of charge and the operational 

mode. The state of charge will appear as text on the top line of the LCD display (e.g. 43%), and in a graphical represen-

tation (e.g. four black blocks for a state of charge from 40% to 49%). The operational mode will appear on the bottom 

line of the LCD display, unless the unit is charging, in which case ‘Charging’ will appear. If the mode is ‘Idle’, the unit 

is ready for use. If the mode is ‘Twilight’, connect a charging power source as described above, and allow the unit to 

charge, at least until the state of charge reaches about 15%. To check whether the unit is ready for use, disconnect or 

turn off the charging power, and press SCROLL to check the mode; if the mode is ‘Idle’, the unit is ready for use. If de-

sired, re-connect (or turn on) the charging power to continue charging. The SBP-1100e does not have to be fully charged 

before being put to use powering a load, and the unit may deliver power to the load while continuing charging.

Control Panel Buttons and the LCD Display

If the LCD display does not respond to pressing the SCROLL and SELECT buttons, wait one minute for the condition to 

correct itself, and try again. If the display still does not respond, press the RESET dot, then wait two minutes, and try 

again.
After pressing the SCROLL or SELECT button, the LCD display will light up and show data for 8 seconds, then blink off. 

During the 8 seconds display time, the data is not updated in real time, so if at any time up-to-date data is needed, 

press the SCROLL button until the desired data set is displayed.
At any time, status messages may appear which will over-ride the data which would otherwise appear in response to 

button presses. Sometimes, a long series of such status messages may appear which may interfere with using button 

presses to obtain data. In that case, wait until the status messages have stopped before again pressing buttons.

Master Reset

The master RESET button is located about ¼ inch to the left of the domed ‘SCROLL’ button. The RESET button is not 

domed to prevent it from being activated by accident. The SBP-1100e may be reset at any time by pressing the button. 

The process takes about two minutes, and the output power will turn off during the reset, then automatically turn on 

when the process is complete.

Battery Charging Using the AC Adapter

If the SBP-1100e Smart Battery Power System is to be charged from an AC power source, connect the AC power adapter 

(

SBP-AC-ADAPTER-24V-130W

) to an AC power source of 100 volts to 240 volts, 50 or 60 Hz. 

When the connection is made, the charging status may be viewed on the control panel display on the SBP-1100e (push 

Summary of Contents for SBP-1100e

Page 1: ...SBP 1100e Smart Battery Power System Software version 4 1 2 User Manual ...

Page 2: ...r damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjustm...

Page 3: ...harging Using DC power sources 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Power to a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port 5 Serial Data Port Connection Specifications 5 Control Panel Buttons 6 LCD Backlighting 6 LCD Panel Indications 6 Storage 8 Outdoor Use 8 Lithium Ion 8 Caution...

Page 4: ... SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to supplying power to the equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is...

Page 5: ...y 10 hr discharge 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load less than 1 hour at 25 deg C 77 deg F 25 3 volts 300 watts 13 8 volts 280 watts 9 volts 180 watts 6 vol...

Page 6: ...tate of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready ...

Page 7: ...solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made th...

Page 8: ...back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the ...

Page 9: ...a Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plu...

Page 10: ...CROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully charged The bar graph indication uses darkened blocks to represent f...

Page 11: ...rging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A ...

Page 12: ...s battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP...

Page 13: ...toring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energ...

Page 14: ...10 Eleven Hundred Energy Corporation ...

Page 15: ......

Page 16: ...12 Eleven Hundred Energy Corporation ...

Page 17: ... 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com ...

Reviews: