background image

 

D  

Battery Charging

 

ELECTRICAL HAZARD 

 

 

WARNING ! 

 

 

PREVENT FIRE 

- Never modify the electrical system. Alterations could cause a fire resulting in serious injury and 
could also ruin the electrical system. 
- Use of the wrong type battery or charger could cause a fire or explosion resulting in serious 
injury. 
- Use of Ultimate Solider

®

 components in products other than Ultimate Solider

®

 M5 Stuart Tank 

could cause overheating, fire or explosion. 

 The battery must be handled by adults only. The battery is heavy and contains sulfuric acid 

(electrolyte). Dropping the battery could result in serious injury. 

 Never allow children to charge the battery. Battery charging must be done by adults only. A child 

could be injured by the electricity involved in charging the battery. 

 Never lift or carry the battery by the wires or connector. This can damage the battery and 

possibly cause a fire resulting in serious injury. Lift and carry the battery by the case only. 

 Read the safety instructions on the battery. 

 Examine the battery, charger and their connectors for excessive wear or damage each time you 

charge the battery. If damage or excessive wear is detected, do not use the charger or the battery 
until you have replaced the worn or damaged part.
 

CAUTION ! 

 

 Use the charger in dry locations only. 

 

Important Notes 

 Your new battery must be charged for at least 18 hours before you use it in your M5 Stuart 

Tank for the first time. 

 We recommend that you start charging your battery before beginning assembly of your new M5 

Stuart Tank. 

 The battery must be upright while charging. 

 The charger is not a toy. 

 Do not short circuit the battery. 

 The battery MUST be removed from your M5 Stuart Tank each time you recharge the lead acid 

rechargeable battery. 

 Before charging the battery, examine the battery case for cracks and other damage which may 

cause sulfuric acid (electrolyte) to leak during the charging process. If damage is detected, do not 
charge the battery or use it in your M5 Stuart Tank. Battery acid is very corrosive and can cause 
severe damage to surfaces it contacts. 

 Do not charge the battery on a surface which could be damaged by the acid contained inside the 

battery. Take precautions to protect the surface on which you charge your battery. 

 Use only a 12 volt (2.0 Amp/Hr.) charger with an input of 120 VAC, 60 Hz

24W and an output of 

12V DC, 2000 mA to charge your rechargeable 12 volt (7.0 Amp/Hr.) battery. 

 If your battery is old and will not accept a full charge, do not leave it in the M5 Stuart Tank. 

Always remove a dead battery from the M5 Stuart Tank. 

 
 

Summary of Contents for RC09037

Page 1: ...d save it For Model RC09037 Use only with a 12 Volt 7 0 Amp Hr Battery 12 Volt 2 0 Amp Hr Charger all included 2 Table of Contents Product features may vary from the pictures above 2003 21st Century T...

Page 2: ...on beginning on page 5 for detailed instructions Read this manual carefully for important safety information and operating instructions before using your M5 Stuart Tank Please keep this manual for fut...

Page 3: ...yte Dropping the battery could result in serious injury Never allow children to charge the battery Battery charging must be done by adults only A child could be injured by the electricity involved in...

Page 4: ...1 510 481 6010 rather than return this product to the store Please identify all parts before assembly and save all packaging material until assembly is complete to ensure that no parts are discarded M...

Page 5: ...battery until you have replaced the worn or damaged part CAUTION Use the charger in dry locations only Important Notes Your new battery must be charged for at least 18 hours before you use it in your...

Page 6: ...TANT The battery must be removed from your M5 Stuart Tank each time you recharge it 1 Using a Phillips screwdriver loosen the screws from the battery hatch Open the battery hatch from the battery comp...

Page 7: ...7 2 Using a Phillips screwdriver loosen the screws from the battery clamp Remove the battery clamp from the battery compartment...

Page 8: ...8 3 Remove the battery connector from the M5 Stuart Tank harness connector 4 Remove the 12 Volt 7 0 Amp Hr battery from the battery compartment...

Page 9: ...s Never charge the battery longer than 30 hours Recharge the battery for at least 14 hours after each use of your vehicle Do not charge the battery longer than 30 hours Once the battery is charged dis...

Page 10: ...olt charger before operating your M5 Stuart Tank for the first time Charge the battery for at least 14 hours after each use of the M5 Stuart Tank Never charge the battery longer than 30 hours Failure...

Page 11: ...11 2 Using a Phillips screwdriver loosen the screws from the battery clamp Remove the battery clamp from the battery compartment...

Page 12: ...nnected to black color battery pole ve and red color wire connector connected to red color battery pole ve Place the 12 Volt 7 0 Amp Hr battery upright in the battery compartment Make sure the battery...

Page 13: ...Plug the battery connector into the M5 Stuart Tank harness connector 5 Position the battery clamp over the battery with the ends of the battery clamp aligned with the screw holes in the battery compar...

Page 14: ...14 6 Insert the screws through the ends of the battery clamp into the battery compartment 7 Tighten the screws with a Philips screwdriver Do not over tighten...

Page 15: ...over and try again Do not force the battery connector into the M5 Stuart Tank harness connector IMPORTANT Always remember to keep the battery hatch locked at all times to prevent children from accessi...

Page 16: ...16 Insert one 9 Volt battery in the proper direction as indicated inside the battery compartment Replace the battery hatch tighten screw securely...

Page 17: ...leakage and corrosion can damage the vehicle Do not store the battery on a surface which could be damaged by the acid contained inside the battery Take precautions to protect the surface on which you...

Page 18: ...ar use Avoid operating the M5 Stuart Tank in wet or snowy conditions Water or moisture in the motors or electrical switches can cause them to corrode and could cause switch or motor failure Avoid oper...

Page 19: ...tion To operate two M5 Stuart Tanks simultaneously slide the Channel Switches of first Tank Body and first Radio Controller to A position and slide the Channel Switches of second Tank Body and second...

Page 20: ...starts to loose power it may experience loss of functions of performance ability If this happens simply recharge your battery again and or replace the radio controller battery Your M5 Stuart Tank is...

Page 21: ...into wall Undercharged battery Make sure power flow to the wall outlet is ON Charger is not working There is no sure way to tell if your charger is working unless you have a volt meter Loose wire or...

Page 22: ...urs after each use Never charge the battery longer than 30 hours Check all connectors Make sure the battery connector is tightly plugged into the charger connector and that the charger is plugged into...

Page 23: ...ILS TO CHARGE n Make sure the lead acid rechargeable battery have been inserted properly n Make sure you have connected your M5 Stuart Tank onto the connectors securely IMPORTANT If you experience a p...

Page 24: ...olutions Guide the vehicle still fails to operate please contact Ultimate Solider Consumer Relations at 1 510 481 6010 Hint For faster service when calling Consumer Relations completely charge the bat...

Page 25: ...lure to follow these instructions will permanently damage your battery Please refer to the Battery Care Section in this manual for more information DO NOT Return your M5 Stuart Tank to the Store If yo...

Reviews: