37
8
Unit-Preferences
SAVE
can be On or Off. This is valid in both unit and kit mode.
VOL
can be Bar showing the volume parameters with a bar graph or
Num showing them with a numerical dB value as well.
MIXER
selects the way the faders are displayed on the UNIT-MIX
page. Either 3 horizontal faders at the time with full names or 9
vertical faders with just the initials (the full names are shown when
selecting or adjusting the faders).
TRIG
sets the top panel button trigger level in dB. The maximum is
0 dB and the minimum -48 dB. It can also be turned off.
FAD
selects the fader name to be edited, turn to choose between
fader 1 to 6. Click to set the cursor at the first character and turn to
change it. Click to increment the cursor position. The assignment of
a drum channel to a specific fader is made on the UNIT-INTF page.
INIT
selects the unit or kit settings to be re-initialized. Either Unit,
Kit1 to Kit100, Kit Program or All. Click to perform the initialization.
If the unit or kit settings were different, Done is shown, otherwise
NoChg. The default is no selection to avoid accidental initialization.
The init data is read from the DrumItInit.dkit file in the root folder.
If one wants to make a personal init settings file, one can copy the
current DrumIt.dkit file and rename it to DrumItInit.dkit.