background image

 

DAY

HOUR

Heating 

DAY 

Program1 

Program2 

Program3 

Program4 

Mon. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Tue. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Wed. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Thu. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Fri. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sat. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sun. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Cooling 

DAY 

Program1 

Program2 

Program3 

Program4 

Mon. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Tue. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Wed. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Thu. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Fri. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sat. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sun. 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Manual Programming   

■  Your  thermostat can  be  programmed  for  weekdays  and  weekends,  or  have  unique 
programs  for  all  7  days.  Use Weekday/Weekend  Programs  or  7-day  Programming  to 
enter or revise programs to match your Personal  Program Schedule. The  same  steps 
are used when entering programs for the first time, or revising programs entered during 
Auto Programming. 
■  Familiarize  yourself  with  Manual  Programming,  so  that  you  can  easily  modify  your 
programs as your comfort needs change. The example below demonstrates the Manual 
Programming method. 

NOTE:   

1. The program time can be set in 10-minute increments, and times remain the same for 
both Heat and Cool programs.   
2. The program temperature can be set in increments of 1

˚F (1˚C). 

3. The Heat set point cannot be set higher than 72

˚F (22˚C), and the Cool 

set point cannot be set lower than 75

˚F (24˚C). 

4. If the system selector is in AUTO mode, the current operating mode will be used for 
programming. 
5.  After  15  seconds  without  a  key  press,  the  thermostat  will  return  to  normal  display 
mode. 
6. When setting the program time, note the AM/PM indicator. 
7. When Auto Recovery ON, the unit will determine how early to turn your system on, so 
that the room is comfortable at the programmed time. 

Weekday/Weekend Programming   
Weekday Programs

 

                  Press                                                                                                            Display Reads                                                                                                         
                                     

 

Normal display of time, temperature,

   

                                         

and day of the week. 

 
 
                                                                                                                                                                 

Step 1                     

 

Selects days Mon to Fri for same set of 4   

programs each day.

 

 

 
   

                                                                                                                                                             
Step 2                     

■ Program indicator(1) is displayed. 

                                 

■ 68

 is displayed. 

                                 

 

                                 

■ Mon to Fri is displayed.

   

                                                                                        

Step 3                     

■ Press and hold until 6:00 is displayed. 

                                 

■ Note AM/PM 

 
 

                                                                                                                                                                                             
Step 4                     

■ Press once to change temperature to 69

.         

 

                                 

 

Weekday program 1 is complete. 

■ Press PROG to move to program 2,3, and 4 

    and follow the same steps. 

           

                                                                                                                                                             

Use                                                                to insert or change time and temperature 

                                                                                      of other programs. 
                                                                                                                                                                   

                                 

 

Selects weekend days Sat, Sun for same 

           

                                     

set of 4 programs each weekend day.

                                     

                                     

■ Follow steps 2-4 to enter programs. 

 
                                                                                                                                                                                                       

Similar to weekday programming.   
 
                                                                                    to insert weekend programs. 
                                                                                                                                                                       

Individual Day Programming   

To program an individual day with it's own program, first select day in the display, then 
insert the desired times and temperatures. 
           

Press                                                                                                    Display Reads                                                                                         

                                   

■ Mon to Fri are selected. Mon to Fri will have   

                                      Same programs.

 

 

 
 
                                                                                                                                                               

■ Sat to Sun will have 

  Same programs.

 

 

 
 
                                                                                                                                                                           
                                   

■ Mon is selected, program for Mon only. 

 
 
 
                                                                                                                                                                     
Use                                                                          to enter programs for Monday. 
 
 
                                                                                                                                                                     
Similarly                   

■Tue to Sunday can be selected.

   

 

 
 
                                                                                                                                                                       
Display the day to be programmed and use   

 
to enter programs. 

                                                                                                                                                                       

NOTE:  Another  approach  to  programming  is  to  first program  all  weekdays  Mon 
through  Fri  and  Sat  and  Sun  as  same programs. Then,  display  and  change  the 
programs of only those days which will have different programs. 
Reviewing Programs     
                                                                                                                                                                 

You  may  want  to  review  the  programs  to  see  that  the  settings  are  compatible  with  your 
lifestyle.   

                                                                                         

 

■ Normal display of current time, day of week 

  temperature, and day of week. 

 
 
.                                                                                                                                                                     

                         

■ 1st weekday program is displayed. 

                         

■ Program indicator(1) appears. 

                         

■ Mon to Fri indication appears. 

 

■Continue pressing                  to view each day. 

 

                         

■Continue pressing                  to view each period. 

                                                                                                                                                                   
If  you  are  armchair  programming  the  thermostat,  before  you  mount  the  face  of  the 
thermostat, turn the system selector to the OFF position. 

Reviewing the Current Temperature Setting     

Current time and temperature. 

 
■ Press less than 1 second . 
■  Set  Temperature  is  shown  above  current  room 

temperature. 

 

OPERATION 
System Selector Switch   

The System Selector Switch on the front of the thermostat determines   
the Operating mode of the thermostat. You may select COOL, OFF,     
HEAT,    AUTO. In order to take full advantage of this thermostat

’s 

feature, we recommend using the AUTO mode. Refer to the Auto Season Changeover 
information on Auto Season Changeover. 

NOTE

: Anytime you install or remove the thermostat from the wallplate, slide the System 

Selector to the OFF position to prevent the possibility of a rapid system On-Off. 

Fan Switch 

The Fan switch should normally be located in the AUTO position. The Fan 
will be turned on along with normal operation of your system. In a normal   
gas or oil furnace, the Fan will be turned on by your furnace after its warm-up   
delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on 
with the system. To run the Fan on continuously, slide the Fan switch to the ON position.   

Temporary Manual Override   

To  temporarily  change  the  current  set  temperature  without 
affecting your program:   
 
■  Press  and  hold              or              for  less  than  1  second  to 
enter Manual Override mode. 
   
■ Press              and              to change to your desired new temperature. 

■ Press to RUN normal mode or wait 15 seconds for it to return automatically. 

■ The current program number will flash to signify the Temporary Override. 

At the next program change, the Temporary Override is canceled, and the next 
program temperature becomes the setpoint temperature.   

To end the Temporary Manual Override:   

■ Press and wait for HOLD to display on the LCD 
■  Press  HOLD  key  twice.  This  will  return  the  set  temperature  to  the  current 

program set temperature.   

NOTE

: The Auto Season Changeover feature will not operate while the thermostat is in 

Temporary  Manual  Override.  Refer  to  the  Auto  Season  Changeover  feature  for  more 
information. 

Permanent Override or a Designated Day Override                                                                           

 

To hold your Manual Override for vacation or Until a Designated Day. 

■ Press to make the current program temperature the   
HOLD temperature. HOLD will be displayed on the LCD,   
and the Program number will disappear. 
■ Follow the Temporary Manual Override instructions above 
  to change the Permanent Manual Override temperature. 
■ You can confirm the held set temperature by pressing for 
less than 1 second. 
■  Press  again.  Hold  day  will  be  displayed  on  the  LCD 
and the clock will disappear 
■Press Day key to add override days. Press Hour key to 
reduce override days 
■  Follow  the  Temporary  or  Designated  Day  Override  instructions  above  to   
change the Permanent Manual Override Temperature. 

 

To end Override:   

Under Permanent Override Press hold/return key twice. Under a Designated 
Day Override press the hold once.  The thermostat will return to the current 
program, and the HOLD display will be canceled. 

NOTE: 

The  Auto  Season  Changeover  feature  will  not  operate  while  the 

thermostat  is  in  permanent  Manual  Override.  Refer  to  the  Auto  Season  Changeover 
feature for more information. 

Auto Season Changeover 

When    the  System  Selector  is  in  AUTO  position,  the  thermostat  will  automatically 
change  between  Heating  and  Cooling  systems,  depending  on  your  program.  We 
recommend  keeping  your  programmed  heating  and  cooling  temperatures  at  least 4

˚F 

(2

˚C)  apart  to  allow  the  Auto  Season  Changeover  to  occur  when  the  appropriate 

temperature  span  has  been  reached.  There  is  a  Temporary  Override  or  Permanent 
Override,  however  these  overrides  are  not  energy  saving  settings.  Auto  Season 
Changeover will still function in Home Today mode, as this is a comfort setting. 
For  example,  you  may  have  the  following  temperatures  programmed  at  a  given  time: 
Heat Set Temp=68

˚F, Cool Set Temp=78˚F 

If the room temperature rises above 78

˚F, then the thermostat will automatically change 

to cool mode and turn on the air conditioner. 
Likewise, the thermostat will automatically change to heat mode and turn on heat when 
the room temperature falls below 68

˚F. 

HOME TODAY     

This patent pending feature allows you to quickly and Temporarily Override your energy 
saving program setting on days when you are normally away from home with one key 
press. 

■ Press to enter the Home Today override. The highest 
program  temperature  for  today  will  be  selected  from 
your  programs  in  Heat  mode  and  become  the  set 
temperature.  (In  Cool  mode,  Home  Today  will  select 
the lowest program temperature for today to be the set 
temperature.) 
■ The display will alternate between “HOME” and the current time. 
■ When pressed during the day, the thermostat will remain in Home Today mode 
until the first program of the next day. 
■If the system is changed between Heat and Cool modes (either manually or by 

Auto  Season  Changeover)  during  the 

“Home  Today”  override  period,  the  setpoint 

temperature  will  be  automatically  update. It  will  automatically change  from  the  lowest 
cool program setpoint to the highest heat program setpoint. 

■ Press to exit Home Today mode before the schedule ending time. ”HOME” is 
no longer displayed on the LCD screen, and the thermostat returns to the current 
program. 
■ You can manually change the setpoint temperature while in Home Today mode. 
Refer to the Temporary Manual Override instructions. Manually changing the set 
temperature while in Home  Today mode will not affect the Home Today ending 
time, However, the set temperature will not change automatically with a manual 
or Automatic change between heating and cooling. 

Energy Monitor

 

■ The Energy monitor feature measures and stores the 
amount of time the heating and air conditioning system 
operates. Usage can be displayed for Today (since 12 
AM), Yesterday, This Week (since Monday), Last Week 
(last  Monday  through  Sunday),  and  Total  (up  to  999 
Hrs). By monitoring your energy usage, you see how much the set-back periods 
are saving, and you can test program adjustment to save even more. To review 
energy usage, press to cycle through Today, Yesterday, this Week, Last Week, 
and  Total.  Press  again  to  return  to  normal  mode,  or  wait  15  seconds  for  the 
display to return to normal mode. You can also return to normal mode at any time 
by pressing RUN. 
■ For example: This LCD display shows Today’s usage to be 10 Hours, 26 
  minutes. 
■ Press and hold for 3 seconds to reset the Energy Monitor’s counters. 

The display will blink, and counters will be cleared to zero. 

NOTE: 

Clearing the Energy Monitor counter will also clear the Filter Monitor counter , as 

Filter  usage  and  Total  Energy  usage  are  the  same.  Also,  clearing  the  filter  Monitor 
counter will clear ALL Energy Monitor counters as well. 

Filter Monitor 

Your  thermostat  also keeps  a  record  of  the  number  of  hours 
your  filter  has  been  in  use.  To  maximize  your  system

’s 

performance and energy efficiency, change or clean your filter 
regularly. 
■ When  the total  system  run  time  for  heat  and  cool  reaches 
500  hours,  you  need  clean  or  change  your  system

’s  filter, 

“FILT”  will  continue  to  flash  until  the  counter  is  set  back  to 
zero. 

■ Press to review total filter usage. The display will blink “FILT” and then show the filter 
Monitor counter. After 15 seconds, the display will return to normal mode, or you can hit 
RUN to exit immediately. 
The Filter Monitor will display up to 999 hours and 59 minutes of usage. In this example, 
the counter is at 410 Hours, 26 minutes. 
■ To reset the Filter Monitor counter, depress the circle key between temperature keys 
(up and down keys) for 3 seconds. The display will blink, and the counter will be reset to 
zero. 

NOTE: 

Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, 

as Filter usage and Total Energy usage are the same. Also, clearing the Energy Monitor 
counters will clear the Filter Monitor counter as well.

 

Auto Recovery 

Auto  Recovery  calculates  how  early  to  turn  your  system  back  on,  so  that  the  room 
temperature  is  already  comfortable  by  the  start  of  the  comfort  temperature  program 
period. Auto Recovery works in both Heat and Cool modes.

 

 

■When the thermostat is in Auto Recovery mode, the display will 
alternate 

“RECO” with time, and the program indicator will flash. 

■Auto  Recovery  can  be  disabled  by  sliding  the Recovery  switch 
on the circuit board to disable. 
■Auto Recovery will not operate if Permanent hold or Temporary hold is in operation. 
■Auto  Recovery  can  be  canceled  manually  if  HOLD  is  pressed  during  the  recovery 
process. 
■Auto Recovery will be canceled and change to next period. 

Details of Auto Recovery Operation: 

■ Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to 

the DISABLE position. 

■ Today is in operation. 
■  Auto  Recovery  can  be  canceled  manually  if  HOLD  is  pressed  during  the  recovery 

process.  If a recovery process is canceled manually then the  recovery process will not 
start again until the next program period starts (an exception is that if time or program is 
changed then the thermostat will check Auto Recovery conditions immediately). 
■ Auto Recovery will be canceled and change to Home Today mode if HOME TODAY is 
pressed during the recovery process. 

Keyboard lock   

This section intentially removed from online manual 

Backlighting   

Your  thermostat  has  an  electroluminescent  lamp  that  backlights  the  display  for  easy 
viewing in the dark. 
When any key is pressed the display is illuminated. 
The  display  will  remain  illuminated  for  8  seconds  after  the  last  key  is  pressed.  This 
allows the light to stay on if you need to operate several keys. 

NOTE: 

If  the  thermostat  is  in  Low  Battery  warning  condition,  the  backlight  will  not 

operate. Replace with 2 new AA alkaline batteries to restore the Backlight function. 

Low Battery Warning 

Your  thermostat has a two-stage low battery warning system. 
When  the  batteries  are  first  detected  to  be  weak,  the  first 
stage  low  battery  warning  is  indicated  by 

“BATT”  flashing  on 

the  LCD  display.  At  your  earliest  convenience,  you  need  to 
replace the batteries with 2 new AA alkaline batteries. 
When the batteries become too weak for normal operation, the 
thermostat enters the second stage low battery warning which 
shuts  down  the  thermostat.  In  this  condition, 

“BATT”  flashes 

alone on the display, and the thermostat will turn your system 
Off. Your system will remain off until the batteries are replaced. 

NOTE: 

The thermostat will still keep the current Set Temperature and Filter run time in 

memory until new batteries are installed. After confirming that new batteries have been 
inserted, the thermostat will return to normal operation. 

Error Mode

 

If  the  thermostat  is  unable  to  control  your  system  due  to  an 
unexpected  battery  problem,  the  thermostat  will  enter  Error 
Mode. In this condition, the thermostat flashes 

“E1”, “E2”, ”E3” 

or 

”E4”  on  the  LCD  display,  and  shuts  off  your  system.  To 

correct  this  problem,  replace  the  batteries  with  2  new  AA 
alkaline  batteries,  even  if  you  have  recently  replaced  them. 
Remove  the  battery,  and  then  hold  any  key  to  release  the 
remaining  charge.    Re-insert  the  battery.  You  will  need  to 
reprogram your thermostat and confirm normal operation. 
If Error Mode returns, please call us for further information. 

Lcd display 

information 

Lcd display 

information 

E1 

Sensor Error 

E3 

No use 

E2 

System switch Error 

E4 

E2 memory Error 

Warning Mode 

If the SYSTEM MONITOR SWITCH is closed the thermostat flashes 
“E5” on the LCD display. 
 

 

Auto Shut Off 

Your thermostat will automatically shut off in Heat mode if the room temperature rises 
above 72

˚F (22˚C). It will shut off in Cool mode if the room temperature drops below 

75

˚F (24˚C). 

Note that if your system has malfunctioned and no longer responds to thermostat 
controls, the Auto Shut-Off will have no effect.

 

TROUBLESHOOTING   

Problem

     

Solution

 

SCRAMBLED OR 
  DOUBLE DISPLAY 
(numbers over   
numbers) 

1. Remove clear mylar sticker.     

NO DISPLAY 

1.  Check battery connections and batteries 
2.  Remove  the  battery,  and  then  hold  any key to  release 
the remaining charge.    Re-insert the battery. 

ENTIRE DISPLAY 
DIMS 

1. Replace Batteries 

PROGRAM DOES   
NOT CHANGE AT   
YOUR DESIRE   
SETTING     

1. Check that the time is set properly to 

“AM” or “PM”   

2. Check that the thermostat is not in 

“HOLD” o r “ Home 

  Today

” mode. 

3. Check for the correct day settings. 

AUTO/FAN DOES 
NOT TURN ON   

1.  Move  Elec/Gas  selector  to  opposite  position  is  in  the 
correct position (

“HEAT,”COOL” or “AUTO”) 

2.  The  thermostat  may  be  in  the  AUTO  Mode.  Look 
for 

”AUTO”  on  the  LCD  display.  If  the  Heat  and  Cool 

program  temperature  are  close,  then  the  thermostat 
requires  a  larger  room  temperature  change  before 
changing from Heat or Cool.   
3.  There  may  be  as  much  as  4  minute  delay  before  the 
Heat  or  Cool  system  turns  on.  Wait  and  check.   
(Compressor protection delay). 
4.  Check  your  circuit  breakers  and  switches  to  ensure 
there is power to the system. 
5. Replace batteries. 
6. Make sure your furnace blower door is closed properly. 
7.  If  your  system  only  uses  4-wires,  be  sure  the  jumper 
wire is installed between the RC and RH terminals. 
8. Check the position of the Furnace or Heat Pump selector 
switches: Normal/O/B. 

ERRATIC DISPLAY               

1. Remove the battery, then hold any key to discharge the 
energy. Then place the battery in again. 

IF UNIT CONTINUES 
TO OPERATE IN THE 
OFF POSITION           

1. Replace unit 
 

THERMOSTAT 
PERMANENTLY 
READS 
“E1”,”E2”,”E3”, “E4”.. 

1. Replace unit. 
 

 

heat 

off

cool

system

auto

on

auto

fan

HOME

TODAY

ENER

HOUR

DAY

PROG

PROG

DAY

PROG

HOUR

MIN

DAY

PROG

DAY

PROG

DAY

PROG

DAY

PROG

HOUR

MIN

DAY

PROG

HOUR

MIN

DAY

PROG

HOUR

MIN

PROG

DAY

PROG

PROG

HOLD
/ RUN

HOLD
/ RUN

HOLD
/ RUN

HOLD
/ RUN

HOLD
/ RUN

HOLD
/ RUN

HOLD
/ RUN

HEAT

2

TEMP

M

H

HEAT

TEMP

3

Mon  

HEAT

AM

1

Mon  

HEAT

AM

1

Mon  

HEAT

AM

1

M

H

Mon  Tue  Wed  Thu  Fri  

HEAT

AM

1

TEMP

Mon  

HEAT

AM

1

TEMP

SET TEMP

1

HEAT

TEMP

Thu  

PM

HOLD

TEMP

HOLD

TEMP

HEAT

TEMP

PM

TEMP

 Sat 

Mon  Tue  Wed  Thu  Fri

AM

1

Mon  Tue  Wed  Thu  Fri

AM

1

PM

TEMP

 Sat 

Reviews: