background image

Body Temperature Measurement – 

Quick Guide

 V 6.1 

L001-L006 of the 

fi

rst line is the metal detection zone from bottom to top, 975 (or other values) of the

second in represents the metal detection sensitivity, high sensitivity for tiny metals.

D001 of the 

fi

rst line is the alarm time setting, and 1.0 of the second line means the alarm time is 1 second.

……

 

Metal detection on setting

 

Press D button in the main interface (display CCCC), press B button to enter the password input interface 

(display 1234), and press B button to shift and C button to adjust to input the password 1111. Press D button 

to display FFFF, indicating the password is correct. Press B button to enter the function setting interface 
(display L001/975). Press B button to shift to 

L 007 / 0 , 

and press B button to shift and C button to adjust to 

change 0 to 975.Press B button to shift to d001 option, and press D button to complete the setting (display 

0000). Press A button twice to return to the main interface.

 

L007 of the 

fi

rst line represents all the 6 metal detection zones. The number 975 of the second line

represents the metal detection sensitivity.

L008 of the 

fi

rst line is the setting to detect small size metals. The number 1 of the second line represents

to detect small size metals, and 50 means not detect small size metals.

D001 of the 

fi

rst line is the alarm time setting, and 1.0 of the second line means the alarm time is 1 second.

Instruction of temperature measurement

 

1.

Power on and wait for 30 seconds, keep nothing in front of the temperature sensor.

2.

Normal ambient temperature is 0°C - 35°C. When using it at - 10°C, you have to decrease the
environment temperature compensation, 5°C per time, until the result difference between it and the
forehead thermometer is less than 

± 

0.3°C.

3.

Measurement method: Measure forehead or wrist surface

4.

Forehead temperature and wrist surface temperature can be measured without adjusting settings.

5.

Measurement area: the center of forehead or the wrist covered by sleeve.

6.

Standard measurement distance: 1cm-10cm (0.39”-3.93” in). When measuring at a distance of 10-30cm
(3.93”- 11.81” in), it is necessary to adjust the environment temperature compensation, 5°C per time,
until the result difference between it and the forehead thermometer is less than 

± 

0.3°C.

36

5

0000

 

1234

 

0000

 

1111

 

0000

 

FFFF

 

975

 

001

 

001

 

36

5

0000

 

1234

 

0000

 

1111

 

0000

 

FFFF

 

975

 

001

 

007

 

975

 

007

 

1

0

d001

 

0000

 

0000

 

36

5

975

 

006

 

1

0

d001

 

0000

 

0000

 

36

5

006

 

Summary of Contents for 2MTHWT-HMD

Page 1: ...WALKTHROUGH METAL DETECTOR Body Temperature Measurement 2MTHWT HMD Quick Guide Manual Version V6 1 REV06122020...

Page 2: ......

Page 3: ...asure thetemperature Temperature measurement module Temperature sensor Real time infrared thermo sensor to detect temperature ready in 30 seconds after power on Distance sensor The distance sensor sta...

Page 4: ...nd metal detected Shifted by button Power Body temperature and Metal safety pass count Shifted by button Power Temperature sensor Power Select Adjust Confirm A B C D Connection Connect the wires with...

Page 5: ...es press D to back Step 4 press D button then press B to shift and C to adjust to enter the password 1319 press D button to enter below Ambient temperature compensation settings Remark 1 The default e...

Page 6: ...ace When the device is not working properly please restore factory settings Low temperature prompt setting Press D button display CCCC in the main interface press B button to enter the password input...

Page 7: ...mes close within 20cm 7 87 in it triggers the thermal sensor to work When the distance is set to 0100 the temperature result is the most accurate The number of 8190 or 8191 showing in the first line i...

Page 8: ...08 of the first line is the setting to detect small size metals The number 1 of the second line represents to detect small size metals and 50 means not detect small size metals D001 of the first line...

Page 9: ...cannot be measured when the machine is started Treatment wait for 30 seconds after power on and then measure the temperature 3 Low temperature measurement Processing method check whether the value set...

Page 10: ...Body Temperature Measurement Quick Guide V 6 1 1 1 Infrared Temperature Sensor Schematic diagram of temperature measurement...

Page 11: ......

Page 12: ...802 Greenview Dr Suite 200 Grand Prairie TX 75050 USA Toll Free 866 708 5401 Fax 214 988 2858 support 2mtechnology net...

Reviews: