background image

2N® TELEKOMUNIKACE a.s., http://wiki.2n.cz

Page 1

2N® Helios IP Security Relay – what it is and

how to use it with 2N® Helios IP intercom?

The 

 is designed for any 

 intercom model with firmware versions 1.15

2N  Helios IP Security Relay

®

2N  Helios IP

®

and higher. It significantly enhances security of the connected electric lock because it prevents the lock from
opening by forced intercom tampering.

Function:

The 

 is a small device installed between 

 intercom which is placed

 Security Relay

2N  Helios IP

®

Helios IP

2N  

®

outside the secured area and the electric lock installed inside the secured area. The interconnection scheme is
shown in the picture below:

The 

 includes a relay that can only be activated if the valid opening code is received

Helios IP Security Relay

2N  

®

from the intercom.

Specifications:

Passive switch: NO and NC contacts, up to 30V/1A AC/DC
Active switch output: typically 8 – 13 V DC depending on power supply (adapter: input voltage minus
0.6V), max 700mA
Dimensions: 56x31x24mm
Weight: 20g

Installation:

Install the 

 onto a two-wire cable between the intercom and the electric lock inside

2

Helios IP Security Relay

N  

®

the area in order to be secured (typically behind the door). The device is powered and controlled via this two-wire
cable and so it can be added to an existing installation. Thanks to its compact dimensions the device can be
installed into a standard mounting box.

Settings for the Helios IP Vario:

The settings are the same as described below, but in addition you need to change the jumpers on the

configuation connector on the PCB to position 

 and Lock Power Supply settings can be set either

normally OPEN

Summary of Contents for Helios IP Security Relay

Page 1: ...ing code is received Helios IP Security Relay 2N from the intercom Specifications Passive switch NO and NC contacts up to 30V 1A AC DC Active switch output typically 8 13 V DC depending on power supply adapter input voltage minus 0 6V max 700mA Dimensions 56x31x24mm Weight 20g Installation Install the onto a two wire cable between the intercom and the electric lock inside 2 Helios IP Security Rela...

Page 2: ...put OUT1 or OUT2 or To the intercom relay output with a 12 V DC serial external power supply Connect the electric lock to the output as follows Helios IP Security Relay 2N To the active 12V 700mA DC output or To the relay output with a serial external power supply The device also supports a Departure button you can use our own order Helios IP Departure button 2N number is 9159013 connected between...

Page 3: ...de both the red and green LEDs blink Activate the intercom switch by using the keypad telephone etc The first code sent from the intercom will be stored in the memory and considered valid After code initialization the Helios IP Security 2N will pass into the operational mode the green LED blinks Relay After these steps you can be sure that nobody will be able to open the door with 12V battery plac...

Page 4: ... very simple Go to section Basic settings Switch 1 and verify that Helios IP 2N this switch is enabled Then you have to choose appropriate Output relay to which is Helios IP Security 2N connected and set Output type to Security mode After that you can also specify codes that will activate Relay the switch as is shown in the picture below ...

Page 5: ...ion Hardware Switches Helios IP 2N Switch 1 and verify that this switch is enabled Then you have to choose appropriate Controlled Output to which is connected and set Output type to Security mode Finally specify codes Helios IP Security Relay 2N that will activate the switch as is shown in the picture below More product information Door Security Intercoms Official Website 2N ...