Installation manual 2N® IP Force
35
/
118
Common Mounting Principles
•
•
Tip
Select flush mounting where possible to make your product elegant looking, more vandal resistant
and more secure.
You can purchase the flush mounting box in advance and hire an installation professional to make
the basic installation work. Moreover, the mounting box helps you align the intercom vertically
(with a deviation of up to 2°).
•
•
•
•
•
•
Caution
Before starting the mechanical installation on a selected place, make sure carefully that the
preparations connected with it (drilling, wall cutting) cannot damage the electrical, gas, water and
other existing wires and pipes.
Make sure that the dowel holes have the required diameter. If the diameter is too large, the dowels
may get loose. Use some suitable building adhesive to keep the dowels in place.
Make sure that the hole depth is sufficient too! The dowel length is 50 mm and the screw length is
90 mm.
Remember that dowels of poor quality may easily get loose and fall out of the wall!
Stainless steel screws are used for the
2N
®
IP Force
assembly. Other screws than stainless steel
ones corrode soon and may aesthetically deteriorate the surrounding environment!
Having removed the front panel, make sure that no dirt gets inside the product (especially onto the
sealing surface and microphone sound guides).
•
•
Caution
The warranty does not apply to the product defects and failures arisen as a result of improper
mounting (in contradiction herewith). The manufacturer is neither liable for damages caused by
theft within an area that is accessible after the attached electric lock is switched. The product is not
designed as a burglar protection device except when used in combination with a standard lock,
which has the security function.
When the proper mounting instructions are not met, water might get in and destroy the electronics.
It is because the intercom circuits are under continuous voltage and water infiltration causes an
electro-chemical reaction. The manufacturer's warranty shall be void for products damaged in this
way!
•
Note
The microphone sound guides are normally loose after the front panel is removed! The screw is
only used as a fall-out protection during installation.
Summary of Contents for IP Force 9151101W
Page 1: ...Installation manual 2N IP Force v 2 18 www 2n com...
Page 49: ...Installation manual 2N IP Force 49 118 2N IP Force Connectors PCB Version 555v3...
Page 50: ...Installation manual 2N IP Force 50 118 2N IP Force Connectors PCB Version 555v4...
Page 65: ...Installation manual 2N IP Force 65 118...
Page 66: ...Installation manual 2N IP Force 66 118...
Page 70: ...Mounting guide...
Page 72: ...Installation manual 2N IP Force 72 118...
Page 73: ...Module setting...
Page 78: ...Installation manual 2N IP Force 78 118...
Page 79: ...Installation manual 2N IP Force 79 118...
Page 80: ...Module setting...
Page 83: ...Active output...
Page 85: ...Installation manual 2N IP Force 85 118...
Page 86: ...Installation manual 2N IP Force 86 118...
Page 87: ...Module setting...
Page 89: ...Security Relay...
Page 94: ...Installation manual 2N IP Force 94 118 Connection...
Page 98: ...Installation manual 2N IP Force 98 118...