2.10.2 Fireman
Description: 1-Button Version
The Fireman audio unit improves the fire fighting operations by setting up top priority
calls to the cabin audio unit in one and the same lift shaft. If any of the machine room
audio units is configured as the control centre (intercom), you can join in the Fireman
call.
Install the Fireman audio unit in a dedicated space that can be easily accessed by
firemen.
The Fireman call has the highest priority, suspending all the other calls (refer to
).
Function Description
Press the button (without detent) to set up the call. The call duration is infinite.
Repress the button to stop the call.
The Fireman call setup is signalled by the Fireman audio unit LED (blue LED shining
around the button).
If the control-centre (intercom) configured machine room audio unit is used, the
Fireman call is signalled by a green LED flashing on the audio unit. Push
(for
longer than 2 s) on the audio unit keypad (green LED shining) to join in the call. Push
(for longer than 2 s) on the audio unit keypad (green LED flashing) to leave the
call without terminating it.
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...