2N TELEKOMUNIKACE a.s., www.2n.cz
119/377
I/O Module – Upper Side
Electrical Installation
Caution
Local power is not supported. Do not connect any local power supply.
The main bus power is sufficient for the I/O Module.
Main Bus Connection
Take the 6-pin main bus connector from the package and connect 6 wires from the
CU maintaining polarity (power + -, audio + -, data + - ) – see the I/O Module cover.
Connect the devices serially (in line). Parallel connection is not allowed. Refer to the
CU section for more details.