120/377
Main bus
1 … Main bus power +
2 … Main bus power -
3 … Main bus audio +
4 … Main bus audio -
5 … Main bus data +
6 … Main bus data -
Warning
Maintain the connection polarity to make the
system work
2N Lift8
®
correctly.
Warning
The bus is electrically isolated from the telephone line circuits according
to the EN60950 requirements and its low voltage cannot cause any
electrical accident.
Termination Resistance
Caution
Find the 3-pin termination resistance connecting jumper between the
main bus connector and lift number switch.
Connect the jumper to the first and last device (CU, splitter or I/O
module) on the bus. Refer to the CU section for more details.
By default, the termination resistance jumper is off.