2N TELEKOMUNIKACE a.s., www.2n.cz
122/377
Logic Input Connection
Up to 4 galvanically isolated logic inputs can be connected to each I/O Module. The
nominal voltage of these inputs is 12–24 V. The minimum detectable level is 8 V and
the maximum level may not exceed 30 V. Otherwise, the I/O Module input circuits will
get damaged. Transition to state 1 occurs with the logic signal rising edge and
transition to state 0 with the falling edge. Every transition is detected and displayed in
the
application. At the same time, every status change is recorded in
2N Service Tool
®
the system log for later use and the user is informed via a pop-up window. See the
figure below for an example of input circuit connection.
Example of Input Circuit Connection
Output Relay Connection
Every I/O Module is equipped with 4 bistable relays with the maximum load of 250 V /
5 A per contact. Never exceed this limit to avoid system damage. When the relay is
closed, the respective LED signals this state. You can configure the relay function in
the
application.
2N Service Tool
®
Example of Output Relay Connection
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...