2N TELEKOMUNIKACE a.s., www.2n.cz
164/377
Par.
No
Parameter name
Range of values
Default value
Note
Info
5 minutes). If the dialtone
is detected again, Lift8
will pass into the "Line
OK" state.
940
Min. dialtone
period
200–2000 ms
400 ms
The tone must be longer
than a half-period of the
busy tone!
942
Min. busy tone
period
100–500 ms
200 ms
These parameters control
the busy tone detection.
944
Max. tone – gap
difference
10–400 ms
50 ms
945
Min. busy tone
period count
2–50
4
1.6.0
Default
value
change
948
Min. ringback
tone time
50–2000 ms
200 ms
The ringtone time is the
length of the section just
before the long gap.
949
Min. long space
time of
ringback tone
100–5000 ms
2500 ms
The longest gap in the
ringing period must be in
an interval between
parameters 949 and 950.
950
Max. long space
time of
ringback tone
500–9999 ms
5500 ms
The longest gap in the
ringing period must be in
an interval between
parameters 949 and 950.
951
Min. ringing
signal time
50–2000 ms
200 ms
Incoming call detection:
The ringtone time is the
sum of sections between
which there is no long
952
100–5000 ms
1000 ms
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...