2N TELEKOMUNIKACE a.s., www.2n.cz
165/377
Par.
No
Parameter name
Range of values
Default value
Note
Info
gap. The longest gap in
the ringing period must
be in the interval
between parameters 952
and 953.
CAUTION! Parameters
951–953 (default values)
work for incoming
ringing.
Min. long space
time of ringing
signal
953
Max. long space
time of ringing
signal
500–9999 ms
6000 ms
961
Max. next digit
pressing time
15–120 s
60 s
Counted from the
transition to a new state
(NOT after the end of
announcement).
962
Min. cabin
ALARM button
pressing time
10–9999 ms
100 ms
A low value is
recommended for
comfortable product
testing.
965
Private mode
0–24 hours
0
Private mode allows
muting of the
microphone on the 2N
®
. Possible setting of
Lift1
this parameter is:
0 – two way audio
enabled always.
1–X, no password in the
rescue mode, time
window when two way
audio is enabled after
success alarm call. After
this time, microphone on
the
is muted.
2N
Lift1
®
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...