2N TELEKOMUNIKACE a.s., www.2n.cz
169/377
Par.
No
Parameter name
Range of values
Default value
Note
Info
Servicing
password
up to 16 digits:
0–9
Change the default
servicing password for
access to programming
via the voice menu and
for full initialisation.
992
Rescue
password
up to 16 digits:
0–9
empty
Set the rescue
terminating password.
993
Enable audio
unit self-test
0–1
0
0 = disabled
1 = An audio test of
selected audio units is
carried out after a check
call.
From
version
1.10.0
994
Enable 4-lift
version
0–1
0
0 = standard connection,
1 = connect up to 4 cabin
Audio Units to the CU
internal splitter as lifts 1–
4 (refer to Subs. 4.5 for
details).
995
Enable
outgoing
machine room
call
0–1
0
0 = disabled,
1 = enabled (if the
parameter is enabled, the
machine room Audio Unit
can be used for outgoing
public network calls).
1001
Enable data
0–1
0
Permit the use of the GSM
/UMTS module
connection to the
provider's data network.
**
1002
APN
Configure the mobile
provider's access APN
server. **
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...