2N TELEKOMUNIKACE a.s., www.2n.cz
37/377
Main bus
6 … Main bus data -
Caution
6-wire
Use unshielded wires of the cross-section of 0.75 mm2.
The maximum total cable length is 30 m with the cross-section of
0.75 mm2.
For higher lengths, enlarge the supply pair cross-section: PWR (60
m – 1.5 mm2 , or 100 m – 2.5 mm2).