background image

SmartGate

 QuickStart 

Read the CD-ROM User Manual carefully to get familiar with all system functions. 

 

Security Precautions 

  Do  not  switch  on  SmartGate  in  the  vicinity  of  medical 

apparatuses to  avoid  interference. The  minimum  distance 
of the antenna and pacemakers should be 0.5 m. 

  Do not switch on SmartGate aboard a plane. 

  Do not switch on SmartGate near petrol stations, chemical 

facilities or sites where explosives are used. 

  Any mobile telephone use prohibition based on RF energy 

radiation applies to SmartGate too. 

  SmartGate  may  disturb the function  of TV sets, radio sets 

and PCs. 

  Warning!  SmartGate  contains  components  that  can  be 

swallowed by small children  (SIM card, antenna, etc.). 

  The  voltage  value  mentioned  on  the  power  adapter  may 

not  be  exceeded.  If  you  connect  SmartGate  to  another 
power  supply,  make  sure

 

that  the

 

voltage  value  is  in  the 

acceptable range. 

  When your SmartGate comes to the end of its operational 

life,

 

dispose of it in accordance with applicable regulations. 

A SmartGate delivery contains: 

SmartGate 

1 pc 

Antenna for direct 
connection 

1 pc 

Antenna with coax cable 

1 pc 

Supply adapter 

1 pc 

Telephone cable 

2 pc 

PC-connection serial cable 

1 pc 

SMS sending input 
connector 

1 pc 

Dowels 

2 pcs 

Screws 

2 pcs 

SW programs and User 
Manual on a CD-ROM 

1 pc 

QuickStart  
mounting pattern 

1 pc 

Warranty certificate 

1 pc 

 

 

Basic Functions 

  The  primary  purpose  of  SmartGate  is  to 

transmit  voice  between  a  GSM  network 
and connected telecommunication devices.

 

  You  can  establish  data  connections 

(GPRS,  CSD)  and  send/receive  SMS  in 
combination with a PC.  

  You  can  send  an  SMS  to  a  pre-

programmed  number  using  the  SMS 
sending input. 

  Models of SmartGate with fax converter 

can  transmit  fax  messages  using 
analog fax Group 3 on telephone line. 

Proper Location 

  SmartGate  is  designed  for  vertical  mounting  on 

suspension  holes  (use  the  mounting  pattern).  This 
position is the best for GSM signal reception.  

  Install  SmartGate  with  respect  to  a  good  GSM  signal 

strength. 

  Place  SmartGate  out  of  range  of  sensitive  devices  and 

human bodies for electromagnetic interference reasons. 

  SmartGate  is  designed  for  indoor  use.  Do  not  place  it 

near heat sources and on sites exposed to direct solar 
radiation.  It  may  not be  exposed to  rain, flowing  water 
and  moisture.  In  addition,  it  may  not  be  exposed  to 
aggressive gas, acid vapours, solvents, etc. 

 

External Antenna Connection 

Screw the antenna into the SMA antenna 
connector. Tighten the antenna connector 
gently with your hand, never use spanner! 
Use  antenna  with  coax  cable  if  the  GSM 
signal is poor, or in case of interference. 
 

SIM Card Installation 

Open 

the 

SIM 

card 

holder 

on 

SmartGate’s  back  side,  insert  the  SIM 
card  and  close  the  holder  properly. 
Select  the  required  GSM  provider  and 
SIM  card  services,  such  as  call 
forwarding, 

call 

barring, 

preferred 

networks,  SMS  centre,  etc.  using  your 
mobile phone before inserting your SIM 
card in SmartGate. 

Telephone Lines Connection 

Connect 

any 

FXO-interface 

equipment 

(standard 

telephone  set,  answering  machine,  PBX  CO  line,...)  to 
FXS interface (Phone icon) on SmartGate. To FXO interface 
on  SmartGate  (crossed  out  Phone  icon)  connect  FXS-
interface  equipment  (internal  line  of  PBX).  SmartGate  is 
equipped  with  CLIP  via  FSK  on  FXS  interface  and  so  it  is 
advantageous to connect a

 

terminal that is able to display the 

CLI. 

 
Power Supply Connection 

SmartGate  is  powered  with  10-16V  DC  voltage.  Where  a 
source  other  than  the  included  supply  adapter  is  used,  the 
voltage  range  and  polarity  shown  on  the  SmartGate  supply 
connector have to be maintained. Do not switch on the power 
supply until the  antenna  is connected to SmartGate to  avoid 
the GSM module damage.  

 

SIM Card PIN protection 

1. Hook  off  the  telephone,  you  can  hear  the  PIN 

tone: 

 

2. Enter the PIN using the DTMF and press a 

 

for  confirmation.  To  cancel  a  wrong  PIN  hang 
up the telephone line. 

3. If  you  hear  the  busy  tone  in  a  while  (a  few 

seconds),  you  have  entered  the  PIN  correctly. 
The PIN will be entered automatically upon the 
next power up. 

4. If  you  hear  the  PIN  tone  again  in  a  while,  you 

have entered a wrong PIN. Re-enter the PIN. 

 

Phone calls – DialThru gateway 

Initial SmartGate behavior is like that: 

  Calls  from  FXS  interface  are  routed  to  GSM 

network. 

  Incoming  calls  from  GSM  rings  on  FXS 

interface. 

  In  case  of  incoming  ringing  on  FXO  interface, 

both  analog  interfaces  on  SmartGate  are 
interconnected.  So  ringing  is  transferred  to 
FXS interface and FXO-FXS call is enabled. 

 

For  advanced  calls  routing  you  have  to 
program 

Routing 

tables. 

Some 

local 

distributors  may  preprogram  tables  for  usual 
use in your country. 

  SmartGate  is  able  to  route  calls  according  to 

phone  number  prefix. Calls from FXS interface 
can  be  routed  not  only  to  GSM  network,  but 
also  to  FXO  interface.  It  is  necessary  to 
program FXS routing table for this. 

 

ME  –  Mobility  Extension

  is  new  useful 

function  on  our  gateways.  If  ME  is  activated 
and  incoming  call  rings  on  FXO  interface, 
SmartGate routes this call to FXS interface and 
simultaneously 

establishes 

call 

to 

GSM 

network.  You  can  receive  the  call  on  analog 
line as well as on your mobile phone. 

 

Phone calls – gateway for PBX internal line 

You  can  switch  SmartGate  from  DialThru 
gateway  to  gateway  for  PBX  internal  line  by 
setting  of  only  one  parameter.  You can find it  on 
FXO routing table page. 

  Calls  from  FXO  interface  are  routed  to  GSM 

network. 

  If incoming calls from GSM network have to be 

routed  back  to  FXO  interface,  it  is  moreover 
necessary  to  program  the  Other  CLI’s  row  in 
GSM  routing  table.  (If  you  want  SmartGate  to 
route incoming GSM calls  according to CLI, fill 
in GSM routing table rows, as you need). 

Analogue FAX and Data Connection (optional) 

SmartGate  with  fax  converter  has  ability  to 
manage  fax  messages  using  analogue  fax 
Group 3  and  data  connection  using  analogue 
modem  connected  to  telephone  line.  The  fax  or 
data  service  must  be  registered  with  your  GSM 
operator.  

 
Outgoing FAX Call and Data Connection 

Before destination  number  dial code 

*01*

 for fax 

call or 

*02*

 for data connection. 

 
Incoming FAX Call and Data connection 

It  is  recommended  to  activate  separate  fax 
number  on  your  SIM  card  –

multinumbering 

scheme

.  Fax  messages  and  data  connection 

should be routed to appropriate number. 
It is  possible to set fax  engine in  the  gateway  to 
receive  the  next  call  as  fax  or  data  call  or  make 
this setting permanent - see the manual on CD. 

 
Indication LEDs 

Power 
supply 

  Light is on whenever SmartGate is 

on. 

GSM 

network 

  light = registered to GSM 

  flashes once in 1s = not registered, 

SIM card inserted 

  flashes once in 3s = not registered, 

SIM card not inserted 

  flashes 4 / 8 times quickly = enter 

your PIN / PUK 

Phone 

line 

  no light = standby 

Orange for FXS interface: 

  flashes quickly = line off-hook or 

ringing 

  light = call FXS – GSM 

  flashes once in 3s = data connection 

in progress 

On FAX models: 

  Flashes 2 times then pause = fax 

connection in progress; after power 
on signalize need of FW upgrade 

Green for FXO interface: 

  flashes quickly = line off-hook or 

ringing 

  light = call FXO – GSM 

Alternately orange and green: 

  quickly = ringing from FXO is 

connected to FXS interface 

  slowly = call FXS – FXO 

 

 
 
The manufacturer, 2N TELEKOMUNIKACE a.s, hereby declares that the 2N SmartGate equipment is in 
compliance  with  the  essential  requirements  and  other  relevant  provisions  of  the  1999/5/EC  Directive. 
The Declaration of Conformity is available on CD-ROM and at website 

www.2n.cz

Reviews: