A-4
Sensor/Alarm Detection
Problems
Possible causes
Actions
There is no
reaction from the
alarm even if the
sensor has
detected an event.
Sensor/Alarm is not set
Set the recording mode to sensor recording and
then select the alarm output port.
You may have used the
wrong type of sensor
Use an A Type sensor
The sensor operation
time is not properly set
Set the sensor operation time
The alarm does
not turn off but
remains on
continuously after
the sensor has
detected input.
The alarm is not
connected
Using a multi-meter, check whether sensor
output is continuously shorted when there
is input
Duration of the sensor
alarm has been set too
long
Adjust the output port operation time for
when the sensor has detected input
Recording is not
working in Sensor
Operation Mode.
The sensor may be
defective
Check sensor operation
The sensor box port
may be defective
Set recording mode to sensor recording type and
short the lower and upper ports of the sensor
box. Check the recording status under these
conditions. If recording
cannot be made to work, contact the authorized
vendor where you bought the product, or the
installer
The selected
channel does not
light up red when I
try to select the
channel connected
to the sensor.
The setting is wrong
Check the recording mode is set to a sensor
Recording type in the schedule setting of the
Relevant channel.
Summary of Contents for H7016
Page 1: ...H7016 User Manual ...
Page 12: ...1 1 Introduction of the product features and components H7016 INTRODUCTION ...
Page 13: ...H7016 User Manual 1 2 ...
Page 19: ...H7016 User Manual 2 2 ...
Page 38: ...H7016 User manual 3 2 ...
Page 55: ...4 1 H7016 SETUP ...
Page 56: ...H7016 User Manual 4 2 ...
Page 92: ...H7016 User Manual 4 38 3 VERSION The version menu displays all the general system information ...
Page 99: ...H7016 User Manual ...