3. Introduction  

3B NET

log

™ is a multimedia data acquisition 

and evaluation system for current and voltage 
measurements and for measurements using 
sensors. The system can be used with or with-
out being connected to a computer. With the 
accompanying 3B NET

lab

™ software, meas-

urements can be conducted with arbitrarily 
chosen parameters as well as in prepared 
experiments. The prepared experiments take 
the user through an interactive experimental 
environment where the measurement parame-
ters have already been defined. When used-
within a network, the teacher and students can 
mutually monitor their results. 
The Ethernet port allows the 3B NET

log

™ unit 

to be directly connected to a local network, so 
that data can be sent to any computer in the 
network for evaluation. In order to use the unit 
with Ethernet an intranet in the same sub-
network must be in place. 
Without being connected to a computer, the 
3B NET

log

™ device can be used as a digital 

multimeter for current and voltage measure-
ments. Combined with different sensors, the 
3B NET

log

™ equipment can also be used as a 

handheld unit with automatic sensor recogni-
tion.  

 
 

4. Technical specifications  

4.1  Analogue inputs  

 

Voltage inputs (channels A and B):  
Measuring equipment:  2 Differential amplifi-
ers  
Measuring range: 

±200mV, ±2V, ±20V 

Surge voltage protection: 

Max. ±40V 

Connections: 

4-mm safety sockets  

 

Current input (channel A):  
Measuring range: 

±200mA, ±2A 

Excess current protection:  Max. ±2.5A 
Connections: 

4-mm safety sockets  

 

Sensor inputs (channels A and B):  
Sensor type: 

Analogue  

Sensor identification:  Automatic  
Sensor connections: 

8-pin mini DIN sockets  

Sampling: Continuous 

 

Sampling rate: 

50k samples/s  

Resolution: 

12 bit  

 

 

 

 

4.2  Analogue outputs (channels A and B)  

Reference point (earth): Common  
Measuring range: 

± 5V  

Connections: 4-mm 

safety 

sockets 

and 8-pin mini DIN 
sockets  

Sampling rate: 

10kSamples/s  

Resolution: 12bit 

 

 

4.3  Digital inputs  

Channels: 

4 (separated into 2 
TTL inputs, one of 
which is a high-speed 
time input, plus 2 in-
puts via optocoupler)  

Sampling rate: 

50k samples/s 
100k samples/s (high-
speed time input)  

Connection: 

8-pin mini DIN socket 

 

4.4 Digital outputs  

Channels: 6 

 

Signal: TTL 

 

Connection: 

8-pin mini DIN socket  

 

4.5 Additional data  

Computer connection:  USB  
Network port: 

Ethernet 

Internal data memory:  128k 
Display: 

64 x 122 matrix for 
measurements and 
units  

Power supply: 

4.5 V DC/300mA or 3 
batteries (AA, LR6 or 
AM3); owing to their 
longer battery life, use 
of alkaline batteries is 
recommended.  

Dimensions: 

21 x 8 x 4 cm

3

 approx. 

Weight: 

400g approx. (includ-
ing batteries) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 3B Netlog 1000009

Page 1: ...og device does not come into contact with water The 3B NETlog device should not be exposed to temperatures above 80 C The operating voltage input is protected against polarity reversal However it is not protected against excess voltage Do not apply voltage in excess of 4 5V to the operating voltage input Use of the Ethernet port requires a power sup ply of higher power rating When using the 3B NET...

Page 2: ...4 1 Analogue inputs Voltage inputs channels A and B Measuring equipment 2 Differential amplifi ers Measuring range 200mV 2V 20V Surge voltage protection Max 40V Connections 4 mm safety sockets Current input channel A Measuring range 200mA 2A Excess current protection Max 2 5A Connections 4 mm safety sockets Sensor inputs channels A and B Sensor type Analogue Sensor identification Automatic Sensor ...

Page 3: ...y lighting on and off briefly press the button Date Time button Switching on the battery and temperature displays Switching on the time display Switching on the date display Selection of operating mode manual or automatic Confirming the display Store button Communication to data logger Scrolling down the menu Selecting Yes or No Confirming the display Rate button Selection of sampling rate Scrolli...

Page 4: ...ia a computer never press the buttons on the 3B NETlogTM console 7 1 Driver installation Before installing the 3B NETlab software it is important to install the USB driver Insert the installation CD into the CD ROM drive of the computer Connect 3B NETlog to the computer via the USB cable The computer reports that it has detected a new hardware Windows XP Do not activate Windows Update Select Insta...

Page 5: ...er Click Yes to confirm that the file should be overwritten 7 2 Software installation Note on installing the software For this software please refer to the installa tion instructions available in the 3B NETlab software manual 8 Operating without a computer Operating a 3B NETlog device without a computer is achieved by using the buttons on the operating panel The functions of these buttons may chan...

Page 6: ...NETlog equipment is ready to conduct measurements 8 6 Setting the sampling rate Press the Rate button the options list for SAMPLE RATE will appear Select the desired sampling rate with the Rate or Store button Press the Date Time button the settings STORE ANALOGUE INPUT 1 STORE ANALOGUE INPUT 2 and STORE BI NARY INPUTS will appear in succession Select YES or NO for each setting with the Rate or St...

Page 7: ... button until the display shows the following Use the Date Time button to confirm this then plug in the Ethernet cable to connect the 3B NETlog unit to the local network Now you can modify the known fixed IP address by pressing the Store or Rate buttons along with Channel or Date Time e g Confirm the address by pressing the Date Time button Now enter or modify the subnet mask e g Confirm the mask ...

Page 8: ...since the beginning of the read opera tion Time remaining shows the approximate time remaining for the read operation Options the following settings can be made here Decimal separator sets the decimal separa tor which is used in exported files Date Time format specifies the time and date format which is used in exported measurement files List left shows the acquired data List right additional sele...

Page 9: ...to search and install older firmware versions 12 Format of exported files Exported files have the following format the words shown here between the delimiters are simply placeholders for actual data Entries are separated by tab characters Depending on the settings some columns may be omitted Date Time Inputs Measurement modes Sampling rate Number of measurement re cords Index tab Absolute date tim...

Page 10: ...oype tested EN 61326 1 Tested for noise immunity and interference Conformity with EU guidelines is indicated by the CE marking on the device 16 Licence 3B Netlog and 3B Netlab are registered trademarks of 3B Scientific GmbH in Germany and other countries The 3B Netlab computer program is pro tected by worldwide copyright It may be used exclusively for educational purposes in schools and educationa...

Page 11: ...3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www 3bscientific com Subject to technical modifications Copyright 2014 3B Scientific GmbH ...

Page 12: ......

Reviews: