background image

5.4  Connection of sensors  

Connected sensors are automatically detected 
by the 3B NET

log

™ device. The following 

status message appears on the display:  
PROBE DETECT…. Subsequently, the meas-
urement and the unit corresponding to the 
connected sensor are displayed.  

 
 

6. Commissioning  

6.1  Operating with the power supply unit  

 

Insert the recessed plug of the power sup-
ply unit into the recessed socket of the 
3B NET

log

™ device.  

 

Connect the power supply unit to the 
mains.  

 

If necessary, press the On/Off button. 

 

6.2  Operating with batteries  

 

Open the lid of the battery compartment 
and insert three batteries (AA, LR6 or 
AM3) while carefully observing the polarity 
(batteries not included).   

 

If necessary, press the On/Off button.  

 
 

7. Operating with a computer and 

3B NETlab™ software  

In order to operate the 3B NET

log

™ equip-

ment with a computer, the 3B NET

lab

™ soft-

ware and a computer with the following system 
requirements are necessary:  

 

Windows XP and Microsoft Internet Ex-
plorer up to version 8  

 

Windows 7 (32-bit and 64-bit) and Micro-
soft Internet Explorer up to 11 or higher 

 

Windows 8.1 (32-bit und 64-bit) and Micro-
soft Internet Explorer up to 11 or higher 

 

32-bit (x86) or 64-bit (x64) processor with a 
speed of at least 1 GHz 

 

At least 1 GB RAM 

 

At least 500 MB hard disc memory

 

 

 

Note

 when operating via a computer,

never press the buttons on the
3B NETlog

TM

 console.   

 

7.1  Driver installation  

Before installing the 3B NET

lab

™ software, it 

is important to install the USB driver:   

 

Insert the installation CD into the CD-ROM 
drive of the computer.  

 

Connect 3B NET

log

™ to the computer via 

the USB cable.   

The computer reports that it has detected a 
new hardware.  

Windows XP:  

 

Do not activate Windows Update.    

 

Select “Install software from specified loca-
tion”.      

 

Under “Browse”, specify the location of the 
driver on the CD. 

 

A hardware message will state that the 
software has failed to pass the Windows 
Logo Test. You should nevertheless click 
“Proceed with installation”.  

Windows 7 and 8.1:  

The operating system automatically installs a 
driver which is packaged with Windows. How-
ever, this driver is not used with 3B NET

log

™. 

The correct driver therefore needs to be in-
stalled manually as per the following instruc-
tions: 

 

Open the hardware manager under 

Control 

Panel -> Hardware and Sound -> Hard-
ware Manager

 

Double click "USB Controller" in the hard-
ware manager. 

 

Double click "USB Serial Converter". 

 

Click 

Drivers -> Update Driver

 

A small window will open so that you can 
search for the driver software. Click "

Find 

driver software on this computer"

 in the 

window. 

 

Click the "

Browse…"

 button and select the 

path for the driver. 

 

Follow the instructions to install the driver. 

 

As an alternative, the folder containing the 
driver file can be copied directly onto the com-
puter from the CD and can be installed from 
the hard disk.       

 

Summary of Contents for 3B Netlog 1000009

Page 1: ...og device does not come into contact with water The 3B NETlog device should not be exposed to temperatures above 80 C The operating voltage input is protected against polarity reversal However it is not protected against excess voltage Do not apply voltage in excess of 4 5V to the operating voltage input Use of the Ethernet port requires a power sup ply of higher power rating When using the 3B NET...

Page 2: ...4 1 Analogue inputs Voltage inputs channels A and B Measuring equipment 2 Differential amplifi ers Measuring range 200mV 2V 20V Surge voltage protection Max 40V Connections 4 mm safety sockets Current input channel A Measuring range 200mA 2A Excess current protection Max 2 5A Connections 4 mm safety sockets Sensor inputs channels A and B Sensor type Analogue Sensor identification Automatic Sensor ...

Page 3: ...y lighting on and off briefly press the button Date Time button Switching on the battery and temperature displays Switching on the time display Switching on the date display Selection of operating mode manual or automatic Confirming the display Store button Communication to data logger Scrolling down the menu Selecting Yes or No Confirming the display Rate button Selection of sampling rate Scrolli...

Page 4: ...ia a computer never press the buttons on the 3B NETlogTM console 7 1 Driver installation Before installing the 3B NETlab software it is important to install the USB driver Insert the installation CD into the CD ROM drive of the computer Connect 3B NETlog to the computer via the USB cable The computer reports that it has detected a new hardware Windows XP Do not activate Windows Update Select Insta...

Page 5: ...er Click Yes to confirm that the file should be overwritten 7 2 Software installation Note on installing the software For this software please refer to the installa tion instructions available in the 3B NETlab software manual 8 Operating without a computer Operating a 3B NETlog device without a computer is achieved by using the buttons on the operating panel The functions of these buttons may chan...

Page 6: ...NETlog equipment is ready to conduct measurements 8 6 Setting the sampling rate Press the Rate button the options list for SAMPLE RATE will appear Select the desired sampling rate with the Rate or Store button Press the Date Time button the settings STORE ANALOGUE INPUT 1 STORE ANALOGUE INPUT 2 and STORE BI NARY INPUTS will appear in succession Select YES or NO for each setting with the Rate or St...

Page 7: ... button until the display shows the following Use the Date Time button to confirm this then plug in the Ethernet cable to connect the 3B NETlog unit to the local network Now you can modify the known fixed IP address by pressing the Store or Rate buttons along with Channel or Date Time e g Confirm the address by pressing the Date Time button Now enter or modify the subnet mask e g Confirm the mask ...

Page 8: ...since the beginning of the read opera tion Time remaining shows the approximate time remaining for the read operation Options the following settings can be made here Decimal separator sets the decimal separa tor which is used in exported files Date Time format specifies the time and date format which is used in exported measurement files List left shows the acquired data List right additional sele...

Page 9: ...to search and install older firmware versions 12 Format of exported files Exported files have the following format the words shown here between the delimiters are simply placeholders for actual data Entries are separated by tab characters Depending on the settings some columns may be omitted Date Time Inputs Measurement modes Sampling rate Number of measurement re cords Index tab Absolute date tim...

Page 10: ...oype tested EN 61326 1 Tested for noise immunity and interference Conformity with EU guidelines is indicated by the CE marking on the device 16 Licence 3B Netlog and 3B Netlab are registered trademarks of 3B Scientific GmbH in Germany and other countries The 3B Netlab computer program is pro tected by worldwide copyright It may be used exclusively for educational purposes in schools and educationa...

Page 11: ...3B Scientific GmbH Rudorffweg 8 21031 Hamburg Germany www 3bscientific com Subject to technical modifications Copyright 2014 3B Scientific GmbH ...

Page 12: ......

Reviews: