4. Operation 

4.1  Turning on 

 

Plug  the  power  supply  into  the  mains  and  con-
nect it to the function generator.  

This immediately turns on the equipment so that it is 
ready to use. The top line of the display will indicate 
the  current  frequency  while  the  bottom  line  shows 
the DC offset and the waveform. 

4.2  Setting the frequency  

 

Use  the  frequency  knob  to  set  the  desired  fre-
quency. 

 

Push in and turn the knob to select the digit to be 
changed on the  display and then turn the knob 
to set the specific frequency.  

The active digit will be indicated on the display by a 
flashing underline character. 

4.3  Setting the offset 

 

Press the 

Offset

 button to activate offset adjust-

ment. 

 

Turn  the  frequency  knob  to  set  the  required 
value in steps of 0.1 V. 

Pressing in the frequency knob resets the value back to 
zero.  

 

When the desired value has been set, Press 

Offset

 

again. 

4.4  Selecting a waveform 

 

Press  the  waveform  button  until  the  waveform 
you want is indicated on the display. 

It is possible to select a sine  wave square  wave or 
triangular wave. 

4.5  Sweep 

 

Press the 

Sweep

 button to activate sweep mode. 

The initial frequency is shown on the top line of the 
display,  while  the  bottom  shows  the  DC  offset,  the 
waveform and the word "START".  

 

Turn the frequency knob to set the desired initial 
frequency as described in section 4.2. 

 

To set the frequency for when the sweep stops, 
press the 

Sweep 

´button again. 

 

The bottom line of the display will show the word 
"STOP". 

 

Turn the frequency knob  to set the desired fre-
quency for when the sweep stops. 

Pressing  the 

Sweep 

button  again  now  sets  the 

equipment into sweep mode. The sub-modes 

Exter-

nal

Internal Continuous

 or 

Internal Single 

will be in-

dicated on the top line of the display. 

 

Turn  the  frequency  knob  to  select  the  desired 
sub-mode for the sweep function. 

 

Press 

Sweep

 again. 

If external mode has been selected, then "EXT" will 
be displayed at the bottom right of the display. If in-
ternal mode was display, the word "TIME" will be dis-
played there. 

 

Adjust the sweep time by turning the frequency 
knob and press 

Sweep 

again

.

 

The start frequency will be shown on the display and 
the word "READY" will appear at the bottom right. 

 

Press 

Offset/Start/Stop

 to start the sweep. 

While  the  sweep  function  is  operating,  the  current 
frequency will be indicated on the top line of the dis-
play, while the bottom line shows the DC offset, the 
waveform and the  word "RUN". The sweep can be 
paused  by  holding  down  the 

Offset/Start/Stop

  but-

ton. Pressing it again allows the sweep to continue. 
The  word  "BREAK"  will  be  displayed  while  it  is 
paused. 

 

To exit sweep mode press 

Sweep 

again. 

In  order  to  modify  the  values,  it  is  necessary  to  exit 
sweep  mode  and  initiate  the  procedure  again.  It 
should be noted that the DC offset cannot be altered 
by this means. 

 

 