1 Coil 
2 4-mm-sockets 
3 Stand 

rod 

4 Securing 

sleeves 

 

 
 

1. Description 

The Helmholtz coils are used to create magnetic 
fields for deflecting electron beams and are at-
tached to the tube holder U19100. The tube holder 
allows the coils to be set up in Helmholtz configura-
tion to generate a highly uniform magnetic field 
perpendicular to the axis of the tube. 

The two air-filled coils are made of lacquered cop-
per wire on a plastic bobbin on an insulating stand 
rod with plastic sleeves for insertion into specially 
drilled holes on the demonstration tube holder. 
Connections are labelled from the start (A) to the 
end (Z) of the coil winding. 

 
 

2. Technical data 

Number of winding 
turns: 320 

each 

Coil diameter: 

136 mm approx. 

Rod: 

145 mm x 8 mm Ø 

Max. current: 
continuous: 1.0 

momentary: 

1.5 A (max. 10 min) 

 

2.0 A (max. 3 min) 

Effective impedance: 

Ω

 approx. 

Connectors: 4-mm 

socket 

Magnetic flux 

B

 in  

Helmholtz-configuration:  

B

 = 

k

 * 

I

, where  

 

   

k

 = appr. 4,2 mT/A 

 
 

3. Operation 

 

Insert the Helmholtz tubes into the holder with 
the connections facing outwards. 

 

Push the sleeves on the rod upwards and insert 
the rod into the holes at an angle.  

 

Push the sleeves into the holes to secure the 
coils.  

 

For series connection, connect socket Z of coil 1 
to socket Z of coil 2 (refer to Fig 1.1). 

 

Take into account the total current when calcu-
lating 

B

 

For parallel connection, connect socket A of coil 
1 to socket Z of coil 2 and socket Z of coil 1 to 
socket A of coil 2 (refer to Fig 1.2). 