background image

TC-SPLIT USER MANUAL

 

 

3C Concept S.A.S 

TC-SPLIT_MANUEL_EN_105.DOCX 

TC-SPLIT 

 

One product, multiple features: 

 

Signal converter: adapt encoder output voltage levels to devices inputs 

(PLC, variable frequency drive …)

 

 

Unipolar / differential converter 

 

Splitter: send encoder signals to multiples devices (4 outputs per 
module, unlimited numbers of chained devices) 

 

Insulator: galvanic isolation between encoder and module outputs, and 
between module outputs themselves. 

 

Multiplexer: Choice of the source encoder signal (using two chained 
modules at least)

 

PDF Manual PDF available at: www.3cconcept.fr/tcusb 

 

Summary of Contents for TC-SPLIT

Page 1: ... frequency drive Unipolar differential converter Splitter send encoder signals to multiples devices 4 outputs per module unlimited numbers of chained devices Insulator galvanic isolation between encoder and module outputs and between module outputs themselves Multiplexer Choice of the source encoder signal using two chained modules at least PDF Manual PDF available at www 3cconcept fr tcusb ...

Page 2: ...equency greater than usual encoder working frequency TC SPLIT Module can be mounted on DIN Rail Module is powered by a DC source voltage between 10 to 30V Typical power is less than 0 5W without encoder or loads A B Z A B Z A B Z A B Z A B Z INT 24V EXT ISO INT 5V A B Z A Z B 0V_EXT V_EXT A B Z A B Z A B Z INT 24V EXT ISO INT 5V A B Z A Z B 0V_EXT V_EXT A B Z A B Z A B Z INT 24V EXT ISO INT 5V A B...

Page 3: ...oltage for NL0 2 P1 1 6 5 V Max allowed voltage P1 1 6 30 V Output 5V INT or EXT Power Max output current Pn 1 6 25 mA Min voltage for NL1 3 Pn 1 6 3 0 V Max voltage for NL0 3 Pn 1 6 0 8 V Output 24V INT or EXT Power Max output current Pn 1 6 25 mA Min voltage for NL1 4 Pn 1 6 21 V Max voltage for NL0 4 Pn 1 6 0 8 V Others Size 130x101x18 mm Protection rating IP20 Operating temperature 5 20 60 C N...

Page 4: ...ncoder with 24Vdc Encoder or signals source Encoder ouput level 5V TTL switch in low pos ON Encoder ouput level 10 30Vdc switch in high pos OFF 3 2 Differential encoder RS422 or HTL differential outputs isolated A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 10 30V 1 0V SLAVE Encoder or signals source Encoder o...

Page 5: ... V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 10 30V 1 0V SLAVE Encoder or signals source Encoder ouput level 5V TTL switch in low pos ON Encoder ouput level 10 30Vdc switch in high pos OFF V Encoder power supply Unipolar wiring must not be used with long cabling distance or within high electromagnetic environments Input voltag...

Page 6: ...ble frequency drive VFD with differentials inputs and power output 5 to 30Vdc Internal power SET Jumpers as decribed Output are not isolated 5V Outputs 24V Outputs Optional 0V wire Variable frequency drive VFD with differentials inputs but no power output 24V 5V 24V 5V Outputs isolation Kind of power supply 1 2 right 2 3 left Not isolated 5Vdc Internal power supply YES 10 30Vdc Internal power supp...

Page 7: ... B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 A B Z A Z B 0V_EXT V_EXT 1 10 30V 1 0V SLAVE External power from PLC NO jumpers Outputs are isolated Programmable logic controller with differentials inputs External independent power supply 12 or 24Vdc Never set Jumpers vertically risk of destruction On RS422 devices 5v max you have to match impedance line by adding 120 Ohms resistors at each line term...

Page 8: ... Output are not isolated 5V Outputs 24V Outputs Optional 0V wire Variable frequency drive VFD with unipolar inputs but no power output Outputs isolation Kind of power supply 1 2 right 2 3 left Not isolated 5Vdc Internal power supply YES 10 30Vdc Internal power supply YES Isolated 5 30 Vdc External power supply YES mean that 2 Jumpers must be set superimposed horizontally Pin 1 of the jumpers is at...

Page 9: ...10 30V 1 0V SLAVE Regulated power supply 12 or 24Vdc Optional switch Opened use internal source Closed external source From master module To slave module Mode Outputs Slave Input Standalone Master TC SPLIT outputs are sourced from TC SPLIT main input P1 Chained Slave TC SPLIT outputs are sourced from Chain IN input which comes from a master module Chain OUT 10V SLAVE input must be left floating if...

Page 10: ...TC SPLIT USER MANUAL 10 3C Concept S A S 10 TC SPLIT_MANUEL_EN_105 DOCX Notes ...

Page 11: ...TC SPLIT USER MANUAL 11 3C Concept S A S 11 TC SPLIT_MANUEL_EN_105 DOCX Notes ...

Page 12: ...TC SPLIT USER MANUAL 12 3C Concept S A S 12 TC SPLIT_MANUEL_EN_105 DOCX ...