background image

3Com Baseline Switch 2848-SFP Plus  

 

V1.0.2.2 Release Notes 

 

 

Page 4 of 5 

3.  

Known Issues for Switch 2848-SFP Plus Release 

1.0.2.2 

3.1  

SFP Frame Loss Issue 

 

Occasionally, when a fibre cable is plugged into an SFP transceiver the SFP port is 
unable to receive frames. This condition can be avoided by ensuring that no frame 
transmissions or receptions occur on this port during link initialization. 

 

The effect of this condition can be observed by checking the port statistics and seeing 
that transmit frame counts are incrementing on this port, but receive frame counts do 
not increment. Frame transmission and reception can be tested by sending ping 
frames through the switch via this port and observing ping responses 
and port statistics. To re-enable frame reception, reset the SFP port by unplugging 
and plugging the fibre cable. 

 
 
 

Reviews: