Viewing Statistics
217
Figure 161
Show Virtual Circuits Detail Window
The Virtual Circuit Statistics Detail screen displays the following statistics:
For further details about conforming CLPO+CLP1 and non-conforming
CLP1+CLP0 cells, see “Conforming/Non-Conforming Cell Counters” later in this
section.
Received
—Total number of cells received (conforming CLPO+CLP1 and
non-conforming CLP1+CLPO cells).
Conf CLP0
—Ingress CLPO; the number of conforming CLP=0 cells received.
ConfCLP1
—Ingress CLP1; the number of conforming CLP=1 cells received.
Nonconf CLP0
—Number of non-conforming CLP=0 cells received. This
counter is used only with
Policing
enabled.
NonconfCLP1
—Number of non-conforming CLP=1 cells received. This counter
is used only with
Policing
enabled.
Dropped (due to congestion)
—Number of cells dropped due to queue
congestion or EPD (early packet discard).
Sent
—Total number of cells sent (total of CLP0 + CLP1 cells).
CLP0
—Total number of CLP=0 cells sent.
CLP1
—Total number of CLP=1 cells sent.
Last Cleared
—Date and time that the statistics were last cleared.
Conforming/Non-Conforming Cell Counters
The conforming and non-conforming cells reflect a cell’s ingress types (CLP0 or
CLP1) prior to any policing actions. These counters do not count a cell more than
once. If a cell is received as a CLP0 type and is then tagged due to policing, the cell
will still be counted as a CLP0 cell.
The following subsections provide additional information that applies to the
conforming and non-conforming cell counters, depending on which policing
configuration you choose.
Summary of Contents for 3C63100-AC-C - PathBuilder S600...
Page 8: ...INDEX 3COM CORPORATION LIMITED WARRANTY ...
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...18 ABOUT THIS GUIDE ...
Page 28: ...28 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 74: ...74 CHAPTER 3 GETTING STARTED ...
Page 230: ...230 INDEX ...