Frame Relay Interworking Functions
The PathBuilder S700 provides two functions to interconnect a frame relay
network with an ATM network:
n
Service Interworking
n
Network Interworking
These interworking features are described in FRF.5 and FRF.8 respectively. As far as
the interworking function is concerned, the major difference between these two
features is that there is no FR-SSCS function required for Service Interworking.
The following sections describe the details of these two functions as well as the
features provided by the PathBuilder S700.
Service Interworking Function
Figure 69 shows an PathBuilder S700 with
Service Interworking function between a Frame Relay and ATM services. In this
setup, a Frame Relay DTE will be communicating with an ATM DTE, but neither
one knows there is a different type of DTE sitting at the other end.
In this interworking scheme, the application on the frame DTE passes its data
through Q.922 core service. It assumes there is an end-to-end pipe to carry its data
from its end to the other DTE at the far end.
Figure 69
Frame Relay/ATM Service Interworking Connection
The Q.922 core sees only a point-to-point link to the next connection point. It has
no knowledge about what type of network is behind the current link. On the
other end, the application residing in ATM DTE passes its data through a NULL
SSCS that sits on top of AAL 5. What this ATM DTE sees is the ATM network to
which it is connected. The PathBuilder S700 sitting in the middle performs all the
required translation and management functions between these two networks and
implements the stacks as indicated above in Figure 69.
ATM
DTE
PathBuilder
S700
Application
Null SSCS
AAL 5
SAR
ATM
PHY
Application
PHY
Q.922
DL Core
ATM
Network
Frame
Relay DTE
Frame
Relay
Network
ATM
Cells
LAPD Frames
Application
PHY
Q.922
DL Core
Null SSCS
AAL 5
SAR
ATM
PHY
PHY
Q.922
DL Core
Frame
Relay DTE
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...