140
C
HAPTER
5: C
ONFIGURING
P
ATH
B
UILDER
S700 M
ODULES
, P
ORTS
,
AND
A
PPLICATIONS
Figure 101
Add Group Menu (Adding UNI Group)
6
Select
[1] Set Admin. Port(s)
. The following prompt appears at the bottom of the
screen:
Enter Admin Port(s) (1..4):
7
Enter the port number(s) of the T1/E1 port(s) you want to include in the UNI
group.
8
Select
[2] Set Admin. Status
and enter
[2]
to put the group in service.
9
Select
[3] Set Number of VPI for VCC
and specify the number of distinct VPIs that
can be used for VCCs on this card:
1-256
. Any VPIs not currently in use by VCCs
are available for VPCs.
10
Select
[3]
Previous Menu.
11
If desired, repeat steps 5-8 to set up a additional UNI groups and put them into
service.
Adding IMA Groups
To set up an IMA group, follow these steps:
1
From the Configuration Management menu, select
[1] Manage Card
to display the
List Card menu, shown earlier in Figure 81.
2
From the List Card menu, select the number corresponding to the slot in which the
DS1 UNI or E1 UNI card is installed to display the DS1 UNI or E1 UNI Configuration
menu, shown earlier in Figure 95.
3
Select
[3] Group Configuration
to display the Group menu, shown earlier in
Figure 99.
4
Select
[2] Add Group
to display the Add Group menu, shown earlier in Figure 100.
5
Enter
[2] IMA
. The Add Group menu appears as shown in Figure 102.
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...