180
C
HAPTER
5: C
ONFIGURING
P
ATH
B
UILDER
S700 M
ODULES
, P
ORTS
,
AND
A
PPLICATIONS
User Error Threshold (N392) / User ME Count (N393)
—These parameters
are related. The
User ME (Monitored Event) Count
is the threshold period that
you set to determine a service-affecting condition. The unit monitors
events—receipt STATUS ENQUIRY messages or expiration of polling timers—for
the number of seconds (
3..10
) that you specify. Within this specified
User ME
Count
period, if an error occurs within the number of seconds that you specify
as the
User Error Threshold
(
3..10
), the system declares an error.
You must set the
User Error Threshold
to a lower value than that of the
User ME
Count
.
Configuring
QSIM/HSIM/FAM Cards
Configuring a QSIM/HSIM/FAM card involves the following tasks:
n
Configuring the card itself
n
Configuring input shapers
n
Configuring virtual interfaces
To configure the QSIM/HSIM/FAM card, follow these steps:
1
Configure the card itself.
a
From the List Card menu, select the number corresponding to the slot in which
the QSIM, HSIM, or FAM is installed: [4], [5], or [6]. The QSIM Configuration
menu, shown earlier in Figure 138, appears.
b
Select
[5] Card Configuration
(
[9] Card Configuration
on the FAM menu) to
display the QSIM, HSIM, or FAM Card Configuration menu. Figure 142 shows
the QSIM Card Configuration menu. The HSIM and FAM Card Configuration
menus are the same. The QSIM, HSIM, and FAM Card Configuration menus
display the current QSIM/HSIM/FAM card configuration and provide options
that allow you to change certain parameters.
Figure 142
QSIM Card Configuration Menu
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...