8
C
HAPTER
1: S
YSTEM
D
ESCRIPTION
Specifications
Table 4 lists complete specifications for the Pathbuilder S700. these specifications
are subject to change without notice.
Table 4
PathBuilder S700 System Specifications
Platform
Configuration
18 slots per shelf
Power Supplies
Up to 6 required depending on number of application modules
installed (load sharing configuration)
Input Power Requirements 90-264 VAC, 50-60Hz standard grounded outlet
-42 to -60 VDC, optional
10 AWG wire, Belden type 19364
Power Consumption
1250 Watts, maximum
Maximum Current
10.0 A @ 110 VAC
5.0 A @ 220 VAC
20.0 A @ -48 VDC
Environmental
Operating Temperature
0 to 45ºC
Storage Temperature
-40 to 70ºC
Humidity
95% @ 40ºC (noncondensing)
Altitude
14,000 ft. or 4,300 meters
Regulatory Compliance
FCC
FCC Part 15 rules for a Class A computing device
FCC Part 68
Emissions
EN55022
EN50082-1
CTR 12
CTR 13
Austel TS-001
Austel AS 3260
Safety
UL listed (UL 1950 and 1459)
VDE/TUV (EN 60950)
EN41003
CSA 22.2
Austel AS/NZS35-48
Physical
Shelf Dimensions
22.75” x 19” x 11.81” (H x W x D)
(57.8 cm x 48.3 cm x 30 cm)
Rack Mount Width
19” (48.3 cm) or
23” (58.4 cm) optional
Rack Mount Spacing
13 RMU
Empty Weight (Base Unit)
62 lbs (28.1 kg)
Unit Weight (fully loaded)
95 lbs (43.1 kg)
Shipping Weight
100 lbs (45.4 kg)
Management
Management Functions
In-band SNMP (See “Configuring In-band Management” in
Chapter 3 for details.)
Dual flash memory (image and configuration) TCP/IP stack (TFTP,
ping, Telnet)
(continued)
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch