210
C
HAPTER
6: P
ATH
B
UILDER
S700 D
IAGNOSTICS
AND
P
ERFORMANCE
M
ONITORING
Relay Power Fuse
Failed
Fuse for external alarm relay is
blown, preventing external
alarms from being generated.
Replace the module, or operate with no
external alarm capability.
SAR Initialize Failure Problem with the SAR chip on
the MCPU. MCPU SAR failed
initialization.
Replace the MCPU card.
Shelf Mismatch
The MCPU is not in the same
shelf as it was the last time it
was powered up.
Information only.
System Clock
Reverted
The system clock has reverted
to a higher priority clock.
Information only. This alarm occurs
only if the
Clock Mode
is set to
Revertive
on the System Clock
Configuration menu.
System power up
System is powered up.
Information only.
Write Session Taken
by Super User
A super user has changed a
read-only session to read-write.
Information only.
Wrong slot for card The card is not in the correct
slot.
Insert the card into the correct slot.
Table 41
MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...