10
C
HAPTER
1: S
YSTEM
D
ESCRIPTION
OC3 UNI
Single-mode
Multi-mode
300 Laser (SDX1155)
wavelength: 1261 nm-1360nm
TX (min) = -15 dBm
TX (max) = -8 dBm
RX (min = -30 dBm
RX (max) = -8 dBm
Reach: -15 km
wavelength: 1261 nm-1360nm
TX (min) = -15 dBm
1300 LED (HFBR-5205)
TX (min) = -19 dBm
TX (max) = -14 dBm
RX (min = -30 dBm
RX (max) = -14 dBm
Reach: -2 km
Line Coding
DS3 UNI
B3ZS
E3 UNI
HDB3
OC3 UNI
CMI
STM-1 UNI
CMI
Line Framing
DS3 UNI
M23 and C-BIT
E3 UNI
G.751-PLCP / G.804 / G.832 for HEC
OC3 UNI
T1.105
STM-1 UNI
G.709
Class of Service
CBR, VBR, VBR-nrt, UBR
Virtual Circuits
Up to 4000 total per PathBuilder S700
Traffic Shaping
Bulk shaping
Per VC/VP shaping
Per VC shaping (Ethernet, FAM, QSIM, HSIM)
Traffic Policing
Per VC
DS1/E1 UNI with Integrated Inverse Multiplexing for ATM (IMA) Modules
Number of Interfaces
nx8,n = 1 to 8; software selectable for individual T1/E1 UNIs or as
logical IMA group (>1 link)
Connector Type
RJ-48 connectors
Integrated CSU
Yes (for DS1)
Line Coding
B8ZS for T1
HDB3 for E1
Line Framing
ESF, SF (D4), or No Framing for T1
G. 703/704 for E1
ATM Framing
HEC (ITU-T G.804), I.432
Payload Scrambling for E1
DSX-1/E1 Interface CBR Module
Interface
ATM Forum CES structured and unstructured (2.0)
Number of Interfaces
4 or 8
Connector Type
RJ-48, 120 ohms balanced or 75 ohms unbalanced
ATM Encapsulation
AAL1
(continued)
Table 4
PathBuilder S700 System Specifications (continued)
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Page 270: ...256 INDEX ...