234
C
HAPTER
6: P
ATH
B
UILDER
S700 D
IAGNOSTICS
AND
P
ERFORMANCE
M
ONITORING
NE Tx Number of Failures (Tx-FC)
—Number of Tx failure alarms at the near end.
NE Rx Number of Failures (Rx-FC)
—Number of Rx failure alarms at the near
end.
FE Tx Number of Failures (Tx-FC-FE)
—Number of Tx failure alarms at the far
end.
FE Rx Number of Failures (Rx-FC-FE)
—Number of Rx failure alarms at the far
end.
DS1 UNI and E1 UNI Port/Link IMA Link ATM Statistics
The T1/E1 Link ATM
Statistics screen lists the following statistics:
Tx Cells
—The number of Tx data cells since the counter was cleared.
Rx Cells
—The number of Rx data cells since the counter was cleared.
Rx ICP Cell Error
—Number of Rx errored ICP cells since the counter was cleared.
Tx Cell Rate
—Current Tx cells per second.
Rx Cell Rate
—Current Rx cells per second.
Rx ICP Cell Error Rate
—Current Rx errored ICP cells per second.
Avg. Tx Cell Rate
—Average Tx data cells rate calculated over the last 8 seconds.
Avg. Rx Cell Rate
—Average Rx data cells rate calculated over the last 8 seconds.
Avg. Rx ICP Cell Err Rate
—Average Rx errored ICP cells rate calculated over the
last 8 seconds.
DS1 UNI and E1 UNI Group Performance Statistics
The T1/E1 Group
Performance screen lists the following statistics:
Running Sec
—Count of operational seconds at the near end interworking group
state machine.
Unavailable Sec
—Count of unavailable seconds at the near end interworking
group state machine.
NE Number of Failures
—Number of failure alarms at the near end.
FE Number of Failures
—Number of failure alarms at the far end.
DS1 UNI and E1 UNI Group ATM Statistics
The T1/E1 Group ATM Statistics
screen lists the following statistics:
Tx Cells
—The number of Tx data cells since the counter was cleared.
Rx Cells
—The number of Rx data cells since the counter was cleared.
Rx ICP Cell Error
—Number of Rx errored ICP cells since the counter was cleared.
Tx Cell Rate
—Current Tx cells per second.
Rx Cell Rate
—Current Rx cells per second.
Rx ICP Cell Error Rate
—Current Rx errored ICP cells per second.
Avg. Tx Cell Rate
—Average Tx data cells rate calculated over the last 8 seconds.
Avg. Rx Cell Rate
—Average Rx data cells rate calculated over the last 8 seconds.
Avg. Rx ICP Cell Err Rate
—Average Rx errored ICP cells rate calculated over the
last 8 seconds.
Summary of Contents for 3C63400-3AC-C - PathBuilder S700 Switch
Page 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Page 18: ...4 ABOUT THIS GUIDE ...
Page 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Page 88: ...74 CHAPTER 3 GETTING STARTED ...
Page 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...