40
C
HAPTER
2: I
NSTALLATION
Table 16
HSSI straight DTE to DCE Cable (50-pin Male to 50-pin Male; Part # 3C63912)
Signal Name
Pin # on DCE
Pin # on DTE
Direction (For DTE)
Circuit GND
1, 7, 13, 19, 25,
26, 32, 38, 44,
50
1, 7, 13, 19, 25, 26, 32,
38, 44, 50
TA
8, 33
8,33
Out
CA
3, 28
3, 28
In
LA
10, 35
10, 35
In
LB
12, 37
12, 37
In
LC
5, 30
5, 30
Out
SD
11, 36
11, 36
Out
RD
4, 29
4, 29
In
TT
9, 34
9, 34
Out
RT
2, 27
2, 27
In
ST
6, 31
6, 31
In
ST DTE
14, 39
14, 39
Out
Ancillary to DTE
(not used)
20, 21, 22, 23,
24, 45, 46, 47,
48, 49
20, 21, 22, 23, 24, 45,
46, 47, 48, 49
In
Ancillary to DCE
(not used)
15, 16, 17, 18,
40, 41, 42, 43
15, 16, 17, 18, 40, 41,
42, 43
Out