92
A
PPENDIX
A: S
PECIFICATIONS
CAUTION:
To remove and replace fan trays and to
maintain proper ventilation for the 8-slot chassis,
keep the rear of the 8-slot Switch at least 91.4 cm
(36 inches) from a wall or other obstruction.
Power
WARNING:
For use in Denmark, each 3CB9EP8
power supply must receive power from a separately
dedicated socket outlet having a 16-ampere fuse in
the installation. This product must be mounted in a
fixed installation such as a permanent rack.
WARNING:
Ved brug i Danmark, skal hver 3CB9EP8
stromforsyning modtage strom fra en separat,
dedikeret stikkontakt med en 16-ampere sikring i
installationen.
Regulatory Compliance
Total power
consumption
1304 watts, 4449 BTU/hour
Output voltage
+5.2 V @ 115 A, +3.5 V @ 175 A,
+12 V @ 2 A, -5 V @ 4 A, +2 V @ 8 A
(+5.2V and +3.5V output is shared)
Input voltage
range
United States — 85 to 132 VAC
International — 180 to 264 VAC
Inrush current
maximum 40 A at 110 VAC
Input frequency
47 to 63 Hz
Safety
CSA 22.2 No. 950
UL1950
TUV GS mark
IEC950, CB Certificate
EN60950, with amendments
Low Voltage
Directive
For products declaring LVD
compliance on the Declaration of
Conformity
This equipment was tested and
found to conform to the Council
Directive 72/23/EEC for safety of
electrical equipment. Conformity
with this directive is based upon
compliance with the safety standard.
EMC Directive
Emissions:
■
EMC EN55022
■
EN61000-3, 2
Immunity:
■
EN50082-1
*EMC Directive Compliance
This equipment was tested and found to conform to the Council
Directive 72/23/EEC for safety of electrical equipment. Confor-
mity with this directive is based upon compliance with the fol-
lowing harmonized standards:
EN55022-Limits and Methods of Measurement of Radio Inter-
ference
EN50082-1 Electromagnetic Compatibility Generic Immunity
Standard: Residential, Commercial, and Light Industry
Summary of Contents for 3CB9E7 - CoreBuilder 9000 Chassis Switch
Page 54: ...54 CHAPTER 4 COREBUILDER 9000 ENTERPRISE SWITCH MODULES...
Page 60: ...60 CHAPTER 5 START THE SWITCH...
Page 74: ...74 CHAPTER 7 MAINTENANCE FOR THE 7 SLOT CHASSIS...
Page 88: ...88 CHAPTER 8 MAINTENANCE FOR THE 8 SLOT CHASSIS AND THE 16 SLOT CHASSIS...
Page 96: ...96 APPENDIX A SPECIFICATIONS...
Page 112: ...112 APPENDIX C INTELLIGENT POWER SUBSYSTEM...
Page 118: ...118 APPENDIX D TECHNICAL SUPPORT...