Switch Fabric Management Module Overview
47
Table 8 lists 9-pin-to-9-pin assignments for connecting your PC to the SFMM.
Table 9 lists 9-pin-to-25-pin assignments for connecting your PC to the SFMM.
High Availability
Operation
To establish a redundant switch management configuration, you must have two
Switch Fabric Management Modules (SFMMs) installed in the chassis. The slots for
management modules are M1 and M2.
A redundant SFMM configuration provides a seamless flow of management
operation. After the failover mechanism reboots the system, there is no loss of
configuration data.
Table 7
Console Port Pinouts
Pin
Signal Name
1
Not Used
2
Receive Data (RD)
3
Transmit Data (TD)
4
Not Used
5
Signal Ground (GND)
6
Not Used
7
Request to Send (RTS)
8
Clear to Send (CTS)
9
reserved
Table 8
RS-232 9-Pin-to-9-Pin Cable Connection Pin Assignments
Signal
SFMM Pin
DTE Pin
Signal
CD
1
N/A
Not Used
RX
2
3
TX
TX
3
2
RX
DTR
4
6
Not Used
GND
5
5
GND
DSR
6
4
Not Used
RTS
7
8
CTS
CTS
8
7
RTS
Reserved
9
N/A
Not Used
Table 9
RS-232 9-Pin-to-25-Pin Cable Connection Pin Assignments
Signal
SFMM Pin
DTE Pin
Signal
CD
1
N/A
Not Used
RD
2
2
TD
TD
3
3
RD
DTR
4
6
Not Used
GND
5
7
GND
DSR
6
20
Not Used
RTS
7
5
CTS
CTS
8
4
RTS
Reserved
9
N/A
Not Used