Power Cord Set—Japan
Important Safety Information
WARNING:
Installation and removal of the unit must be carried out by
qualified personnel only.
WARNING:
If installing the Switch 4200G together (one on top of the
other) with SuperStack II or SuperStack 3 units that are shallower than
the 4200G, the Switch 4200G unit must be installed below the shallower
units.
WARNING:
The unit must be earthed (grounded) or must be connected
to an earthed power supply to ensure compliance with safety standards.
WARNING:
Power Cord Set:
This must be approved for the country where it is used:
U.S.A. and
Canada
■
The cord set must be UL-approved and CSA certified.
■
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
■
The cord set must have a rated current capacity of at least
10A.
■
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,
250V) configuration.
United
Kingdom only
■
The supply plug must comply with BS1363 (3-pin 13 amp)
and be fitted with a 5A fuse which complies with BS1362.
■
The mains cord must be <HAR> or <BASEC> marked and
be of type H03VVF3GO.75 (minimum).
10014914AA.book Page 76 Friday, July 7, 2006 2:08 PM
Summary of Contents for 4200G PWR
Page 4: ...10014914AA book Page 4 Friday July 7 2006 2 08 PM ...
Page 30: ...30 CHAPTER 2 INSTALLING THE SWITCH 10014914AA book Page 30 Friday July 7 2006 2 08 PM ...
Page 74: ...74 CHAPTER 5 UPGRADING SOFTWARE 10014914AA book Page 74 Friday July 7 2006 2 08 PM ...
Page 92: ...92 APPENDIX B PIN OUTS 10014914AA book Page 92 Friday July 7 2006 2 08 PM ...
Page 96: ...96 APPENDIX C TECHNICAL SPECIFICATIONS 10014914AA book Page 96 Friday July 7 2006 2 08 PM ...
Page 104: ...10014914AA book Page 104 Friday July 7 2006 2 08 PM ...