3
Temperature and Humidity Requirements
The operating temperature and humidity requirements are as follows:
Specification
Range
Operating temperature
-10°C to 55°C (14°F to 131°F)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
Operating humidity (non-condensing)
5% to 95%
Power Supply
The AP9152 supports PoE power supply.
3 Installing the AP
Note:
1) Make sure that no metal particles (such as screws) fall into the Ethernet or
console interface during installation.
2) Before installing the AP9152 to the wall-mounting bracket, connect the
network cable. The network cable can only be UTP Cat-5.
3) Before connecting the console cable to the AP9152 for debugging or pressing
the reset button, you need to remove the device from the wall-mounting
bracket.
Determining the Installation Site
Determine the installation site by observing the following principles:
z
Ensure that there are as few obstacles as possible between the AP and the
wireless stations.
z
Keep the AP far away from electronic devices (such as microwave ovens) that
may generate RF noise.
z
Ensure that the installation site will not cause any inconvenience or nuisance.
Note:
1) Make sure the ceiling is strong enough and the structure is suitable for ceiling
mounting. Reinforce the ceiling if needed.
2) Use a Kensington lock if physical security is required to protect the AP from
being stolen.
Installing the AP
The AP9152 supports three installation methods:
z
Mounting the AP on a Wall
z
Mounting the AP on a Ceiling
z
Mounting the AP to a T-Rail
Mounting the AP on a Wall
The following describes how to mount the AP9152 on a wall: