214
C
HAPTER
10: S
WITCH
R
EDUNDANCY
Manual configuration of the redundant switch parameters listed in the
table above must be done on a CoreBuilder 7000 other than the active
one. Only upon configuration completion can the redundant switch be
utilized in the active CoreBuilder 7000.
Information Based on
the MAC Address
When the redundant switching module takes over, it is assigned the IP
address of the active switching module. However, each switching module
board has a unique MAC address burned into its EPROM. This MAC
address is used by the CoreBuilder 7000 for three purposes:
For the IP stack
For the LES ATM address user part
For calculating a unique number to be assigned to the ELAN name
The ELAN names have the format ELANxxxx_y where xxxx is a unique
number calculated using the MAC address and y is an integer from 0 to
15 automatically assigned to each of the 16 default LESs of the
CoreBuilder 7000. In this way, each LES has a unique ELAN name and
unique ATM address.
When a redundant switching module takes over from the active
switching module, the IP address, the ELAN names, and LES address
remain the same as they were in the active module.
Network prefix significant length
CoreBuilder 7000 active LECS address
Built-in LES ATM addresses
Built-in LES names elanXXXX_Y (ELAN
name)
NNI/UNI port setup
NNI maximum number of hops for all
ports
Table 50
Updating Configuration Database (continued)
Data Transferred from Active to
Redundant Switch
Data to be Updated Manually in
Redundant Switch
Summary of Contents for CoreBuilder 7000
Page 12: ......
Page 30: ...30 CHAPTER 1 ATM NETWORK BASICS...
Page 32: ...32 CHAPTER 1 ATM NETWORK BASICS...
Page 34: ...34 CHAPTER 1 ATM NETWORK BASICS Figure 8 LANE Network over WAN...
Page 96: ...96 CHAPTER 4 PRIVATE NETWORK TO NETWORK INTERFACE PNNI VERSION 1 0...
Page 184: ...184 CHAPTER 7 LAN EMULATION VERSIONS 1 0 AND 2 0...
Page 206: ...206 CHAPTER 9 DEVICE MANAGEMENT...
Page 222: ...222 APPENDIX A TECHNICAL SUPPORT...
Page 234: ...234 APPENDIX B PROTOCOLS AND INTERFACES...
Page 238: ...238 APPENDIX C COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS...
Page 242: ...242 APPENDIX D SAFETY INFORMATION...