ILMI Setup
137
Enable/Disable ILMI
Channel Polling
Enables or disables ILMI channel polling and saves the ILMI channel
polling status for the specified port in the CoreBuilder 7000 family ATM
switch. For more information, “ILMI Connectivity Polling” on page 41 in
the Operations Guide.
ILMI channel polling must be enabled if the change of attachment-point
facility (COAP) is enabled (see
“Enable/Disable Change of
Attachment-Point” on page 148
).
To set the polling interval, see “Update ILMI Channel Polling Interval” on
page 139.
Command Actions
Command Result
Example
Enter:
1 1 8 5 2
3.2 1
The following message is displayed:
ILMI polling is set to ENABLED
The polling status of port 2 in slot 3 is enabled and is saved to flash.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(8) IME: ILMI setup
(5) POL: Polling setup
(2) SST: Set&Save Polling status
Enter a parameter at the prompt
Parameter
Format or Range
Port ID
slot.port
ILMI polling
enable/disable
0
to disable ILMI polling
1
to enable ILMI polling
Direct access sequence:
1 1 8 5 2
[parameters]
System action taken:
ILMI polling for the selected port is updated
immediately and is saved in flash.
System message display:
ILMI polling is set to ENABLED/DISABLED
Summary of Contents for CoreBuilder 7000
Page 16: ......
Page 68: ...68 CHAPTER 3 GENERAL TASKS ...
Page 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Page 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Page 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Page 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Page 476: ...476 APPENDIX C SAFETY INFORMATION ...
Page 514: ...514 INDEX ...