166
C
HAPTER
7: C
ONFIGURING
V
IRTUAL
C
HANNELS
Calls routed to an ATM address are differentiated by their
Call ID.
The Call
ID is allocated by the switch at the time the call is initiated and uniquely
identifies the call in the CoreBuilder 7000.
More than one call can be routed to a single ATM address at one time.
For example, when a bridged Ethernet LAN is attached to a single LEC, all
calls to the stations on the LAN are transmitted to that LEC’s ATM
address.
If you do not know the Call ID of the call whose information you want to
display, enter 0 for the Call ID and a list of calls routed to the ATM address
are displayed together with their Call IDs. You can read the desired Call ID
from this list according to the VPI/VCI number, for example.
Command Actions
Command Result
Call Parameters
Table 23 shows the call parameters displayed by the command.
Enter the menu sequence:
(3) CON: Connections
(2) RTG: Routing
(1) CLL: Calls
Enter a parameter at the prompt
Parameter
Format or Range
For SVC: ATM address
member
For PVC: Port ID
‘slot’’port’’sequential number’
For example: 1102
slot.port
Call ID
n
(
0
for all calls)
Direct access sequence:
3 2 1
[parameters]
System action taken:
The information for the specified call is displayed.
System message display:
Information is displayed as shown in the examples on
pages 169, 170 and 171.
Summary of Contents for CoreBuilder 7000
Page 16: ......
Page 68: ...68 CHAPTER 3 GENERAL TASKS ...
Page 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Page 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Page 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Page 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Page 476: ...476 APPENDIX C SAFETY INFORMATION ...
Page 514: ...514 INDEX ...