Create Permanent Virtual Channel (PVC)
183
Create UBR PVC —
Quick Setup
Sets up UBR PVC call using the default for parameters not explicitly set.
Default values for Cell Loss Level, Priority, and Cell Loss Priority are used
(see Table 28). The same limits as full PVC call setup apply. For more
information, see “Permanent Virtual Channels” on page 100 in the
Operations Guide.
Command Actions
Command Result
Example
Enter:
3 4 1 2 p2p 5.1 0 37 5.2 0 381
The following message is displayed:
A new PVC was created with call id: 9.
Enter the menu sequence:
(3) CON: Connections
(4) S&C: Setup and Config Conns
(1) PVC: PVC operations
(2) CRP: Create PVC call
Enter a parameter at the prompt
Parameter
Format or Range
Call type
P2P
for point-to-point PVC
P2M
for point-to-multipoint PVC
First port ID
slot.port
First port VPI
See (
3)CON\(4)S&C\(1)PVC
for VPI/VCI limits
First port VCI
See (
3)CON\(4)S&C\(1)PVC
for VPI/VCI limits
Second port ID
slot.port
Second port VPI
See (
3)CON\(4)S&C\(1)PVC
for VPI/VCI limits
Second port VCI
See (
3)CON\(4)S&C\(1)PVC
for VPI/VCI limits
Direct access sequence:
3 4 1 2
[parameters]
System action taken:
A PVC with the required parameters is created.
System message display:
A new PVC was created with call id:
Summary of Contents for CoreBuilder 7000
Page 16: ......
Page 68: ...68 CHAPTER 3 GENERAL TASKS ...
Page 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Page 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Page 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Page 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Page 476: ...476 APPENDIX C SAFETY INFORMATION ...
Page 514: ...514 INDEX ...