Signaling Setup
195
Signaling Setup
The following commands allow you to configure the ILMI signaling
parameters.
■
Display VPI/VCI Range
■
Update VPI/VCI Range
■
Save VPI/VCI Range
■
Display Signaling Protocol Profile
■
Update Signaling Protocol Profile
■
Display Signaling Protocol Version
■
Update Signaling Protocol Version
■
Save Signaling Protocol Configuration
■
Display CALL-PROCEEDING Suppression Status
■
Update CALL-PROCEEDING Suppression
■
Display Signaling Stack Capacity
For information about signaling setup, see “Signaling — External Links”
on page 104 in the Operations Guide.
Display VPI/VCI
Range
Displays the current UNI (Q93B) signaling protocol VPI/VCI configuration
parameters for a specified port. Maximum and minimum VPI/VCI values
are displayed for each port.
These parameters are set to match the VPI/VCI capabilities of the device
attached to the specified port. If an end-station or edge-device is
attached to the port, it frequently has limits on the VPI/VCI channels it
can handle. Configure the CoreBuilder 7000 family ATM switch port to
match these limits.
These parameters can be set independently for each port.