268
C
HAPTER
9: M
ANAGING
LAN E
MULATION
S
ERVICES
MPOA Devices
Configuration
The switch allows configuration of MPOA entities: MPS and MPC. The
configuration is general so that all MPSs and MPCs that request
configuration receive the same parameters.
Display Current MPS
Configuration
Displays all the current settings of the MPS variables.
Command Actions
Command Result
Example
Enter:
2 5 1 1
The following information is displayed:
Enter menu sequence:
(2) LEM: LAN Emulation
(5) MPA: MPOA Devices Configuration
(1) MPS: MPOA Server Configuration
(1) DIS: Display current config
Direct access sequence:
2 5 1 1
System action taken:
All the current settings of the MPS variables are
displayed.
System message display:
Information is displayed as shown in the example
below.
MPOA Server Configuration
-------------------------
MPS-p1
keep-alive time:
10 (seconds)
MPS-p2
keep-alive lifetime:
35 (seconds)
MPS-p3
internetwork-layer protocols:
{}
MPS-p4
MPS initial retry time:
5 (seconds)
MPS-p5
MPS retry time maximum:
40 (seconds)
MPS-p6
MPS give up time:
40 (seconds)
MPS-p7
default holding time:
20 (minutes)
Summary of Contents for CoreBuilder 7000
Page 16: ......
Page 68: ...68 CHAPTER 3 GENERAL TASKS ...
Page 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Page 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Page 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Page 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Page 476: ...476 APPENDIX C SAFETY INFORMATION ...
Page 514: ...514 INDEX ...