402
C
HAPTER
13: C
ONFIGURING
AND
M
ANAGING
PNNI (F
OR
THE
E
XTENDED
V
ERSION
O
NLY
)
Set PTSE Lifetime
Factor
Sets the PTSE lifetime factor value. The PTSE lifetime factor is the value
used to calculate the initial lifetime of a PTSE. The PTSE refresh interval is
multiplied by this percentage to obtain the initial lifetime factor. A change
to the PTSE lifetime factor value takes place after the next reboot.
Command Actions
Command Result
Example
Enter:
1 1 10 4 3 4 6 150
The following message is displayed:
Default Value is 200, new value is 150
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(6) PLT: PTSE Lifetime Factor
Enter a parameter at the prompt
Parameter
Format or Range
lifetime factor
101% - 1000%
Direct access sequence:
1 1 10 4 3 4 6
[parameters]
System action taken:
The Hello inactivity factor is displayed and is updated
to its new value.
System message display:
Default value is <x>, new value is <y>
Summary of Contents for CoreBuilder 7000
Page 16: ......
Page 68: ...68 CHAPTER 3 GENERAL TASKS ...
Page 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Page 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Page 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Page 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Page 476: ...476 APPENDIX C SAFETY INFORMATION ...
Page 514: ...514 INDEX ...