Setting Up for Management
75
Update Default
Gateway Address
Updates the Default Gateway address of the CoreBuilder 7000 family
ATM switch. The default factory Default Gateway address is 0.0.0.0. The
default gateway address is updated after the next reboot of the switch.
Command Actions
Command Result
Example
Enter:
1 1 2 3 2 100.1.0.254
The Default Gateway address is updated to 100.1.0.254.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(2) MNG: Management setup
(3) GWY: Default Gateway Setup
(2) SGW: Set & Save Default Gateway
Enter a parameter at the prompt
Parameter
Format or Range
Default gateway address valid IP address
Direct access sequence:
1 1 2 3 2
[parameters]
System action taken:
The default gateway address is updated after the next
reboot of the switch.
System message display:
Default gateway address was
successfully set.