2-6
C
HAPTER
2: I
NSTALLATION
Figure 2-3
Installing the Ethernet Interface Module
c
Continue to slide the module into the slot until you feel a slight
resistance.
This resistance is caused by the connector on board engaging the
connector on the motherboard.
2
Fasten the module into the chassis with the two screws.
Mounting the
Server
You can mount a CS/3000 series server on a tabletop, in a two- or four-pole
19-inch rack, or vertically in a wall mount. It is usually easier to mount the
server before attaching cables
Mounting on a
Tabletop
To mount your server on a tabletop, use the following procedure:
1
Place the server on a firm, flat surface.
Do not mount the server at an angle greater than 15 degrees from the
horizontal or vertical.
2
Make sure that the air intake and fan exhaust vents on the sides of the
cover are not blocked.
Leave at least 5 inches (13 cm) of free space on both sides.
CS3000BookFile Page 6 Tuesday, October 15, 1996 5:12 PM