8
Transparent Polled Async
Configuration
This table provides a quick reference for identifying which parameter is used when
the Data Forwarding Criteria (#115) parameter is set to 0, 1, or 2.
Data Forwarding Criteria (#115)
Range:
0 to 2
Default:
0
Description:
Specifies the criteria for determining the end of an asynchronous
message sent from an asynchronous device. When Data
Forwarding Criteria settings are satisfied, the asynchronous
message is sent into the X.25 network.
• 0: Normal. Select Data Forwarding Character (#3) or Idle
Timer Delay (#4). NOTE: These two parameters should
not be used simultaneously.
• 1: Short Timer. Short Timer Duration (#116) is used to
provide a short idle timer delay in place of the standard idle
timer period.
• 2: RTS Signal Drop. The asynchronous message is
terminated when the RTS signal is dropped by the attached
device and data is automatically forwarded. No other
settings are required.
Note
If parameter #115 is set to 2, you cannot have the port record
connection type = DIMO, DIMOa, or DIMOb, because when RTS
drops the connection is broken. Refer to the Configuration Basics
Guide for descriptions of connection types.
When Data
Forwarding Criteria
(#115) is set to...
The Following Parameter Is Used...
0
Data Forwarding Character (#3)
or Idle Timer Delay (#4)
1
Short Timer Duration (#116)
2
No specific parameter used. Data is automatically
forwarded when the RTS signal drops.
Note
When Data Forwarding Criteria (#115-0) is used, select either #3 or #4. These
parameters should not be used simultaneously.