Bridging
83
T0008-16F
Release 5.2M
Bridge Filtering
Outgoing NetBIOS Name Link Action
Range:
PASS, BLOCK, PASSLIST, BLOCKLIST
Default:
PASS
Description:
These are the options that you can define for the link
• PASS
— Passes outgoing frames with the specified NetBIOS
name on all links. All outgoing frames with other NetBIOS
names are blocked on all links.
• BLOCK — Blocks outgoing frames with the specified
NetBIOS name on all links. All outgoing frames with other
NetBIOS names are passed on all links.
• PASSLIST — Passes all outgoing frames on the links that you
listed in the List of Links parameter. Blocks all the outgoing
frames on the links that are not listed. An empty list means
that all links block the frames.
• BLOCKLIST — Blocks all outgoing frames on the links that
you listed in the List of Links parameter. Passes all the
outgoing frames on the links that are not listed. An empty list
means that all links pass the frames.
Note
If you chose PASS or BLOCK, skip the List of Links parameter.
Outgoing NetBIOS Name: List of LInks
Range:
1, 5 to 36
Default:
The individual numbers correspond to the links that you filter
according to the preceding parameter.
Description:
The following describes the options that you can define for the
link:
• PASSLIST — Passes all outgoing frames on the links that are
listed. Blocks all the outgoing frames on the links that are not
listed. An empty list means that all links block the frames.
• BLOCKLIST — Blocks all outgoing frames on the listed
links. Passes all the outgoing frames on the links that are not
listed. An empty list means that all links pass the frames.
Summary of Contents for PathBuilder S200 Series
Page 1: ...3Com Corporation PathBuilder S200 Series Switch Bridging ...
Page 4: ......
Page 22: ...18 Bridging Bridge Hardware Components in PathBuilder S200 Series Switches ...
Page 152: ...148 Bridging Bridge Statistics ...
Page 161: ...Index 5 ...