IPX Configuration Commands
501
Example
Set the maximum size of SAP updating packet on the interface Ethernet1/0/0 to
674 bytes (carrying 10 service information items at most).
[3Com-Ethernet0/0/0] ipx sap mtu 674
ipx sap multiplier
Syntax
ipx sap multiplier multiplier
undo ipx sap multiplier
View
System view
Parameter
■
multiplier: It is used to calculate the aging period of SAP service information
table items, ranging from 1 to 1000. By default, the value is 3. When the
updating interval is 60 seconds, the aging period is 60*3 = 180 seconds.
Description
Using the ipx sap multiplier command, you can configure the aging period of SAP
service information table items. Using the undo ipx sap multiplier command, you
can restore the default value of SAP aging period.
By default, the aging period of SAP service information table items is 3 times of
SAP updating interval.
For the related command, see ipx sap timer update.
Example
Set the aging period of SAP service information table items is 5 times of updating
interval.
[3Com] ipx sap multiplier 5
ipx sap timer update
Syntax
ipx sap timer update seconds
undo ipx sap timer update
View
System view
Parameter
■
seconds: SAP updating interval, ranging from 10 to 60000 seconds. By default,
the value is 60 seconds.
Description
Using the ipx sap timer update command, you can configure SAP updating
interval. Using the undo ipx sap timer update command, you can restore the
default value of SAP updating interval.
When an interface adopts trigger update method, the command configuration
does not take effect.
Summary of Contents for Router 3000 DSL Series
Page 6: ......
Page 686: ...686 CHAPTER 6 ROUTING PROTOCOL ...
Page 758: ...758 CHAPTER 7 MULTICAST COMMON CONFIGURATION COMMANDS ...